Maintenance; Principales Componentes - Skymsen SL-218 Manual De Instrucciones

Ocultar thumbs Ver también para SL-218:
Tabla de contenido

Publicidad

6. Maintenance

Maintenance must be considered a set of procedures with the purpose to keep the
equipment best opera ng condi ons , therefore increasing the equipment life and safety.
Cleaning – check item 3,3 Cleaning
Wiring - Check all wires regarding deteriorate condi ons as well as all electric contacts
(terminals) regarding ghtening and corrosion .
Contacts – ON/OFF switch, emergency bu on, reset bu on , electronic circuits etc , check
the equipment in order to assure that all components are correctly working and the
equipment opera on is normal .
Installa on – make sure the installa on followed item 2.1 instruc ons
Life span: 2 years considering a normal working hours journey
1 – Each month check :
- Check the electrical installa on
- Measure the voltage at the socket
- Measure the working current and match it with the nominal current
- Check the ghtening of all electric terminals to avoid bad contacts
- Check electric motor sha clearance
- Check the wiring for overea ng , insula on failures and mechanical damages .
2 Each three month checks
- Check electrical components such as ON/OFF switch, emergency bu on , reset bu on,
electronic electric circuits , overea ng, insula on failings, or mechanical damages
- Check bearings clearances
- Check retainers, O'rings, V'rings and other seals
22

1.2 PRINCIPALES COMPONENTES

Todos los componentes que incorporan la maquina son construidos con materiales
cuidadosamente seleccionados para su función, dentro de los padrones de prueba y de la
experiencia de SIEMSEN.
02
05
06
07
08
14
13
01 - Manija del Calibrador de la Hoja
02 - Llave Prende/Apaga
03 - Puerta
04 - Volante Superior
05 Manija
06 - Guía de la Hoja
07 - Hoja
08 - Mesa Movible
09 - Presilla
10 - Regulador de Corte
11 - Mesa Fija
12 - Volante Inferior
13 - Pies
14 - Gabinete
01
03
04
10
11
12
09
27

Publicidad

Tabla de contenido
loading

Tabla de contenido