Normal Operation
The default operating mode keeps the dehumidifier
running at its maximum capacity. This is ideal for
most restoration application To control humidity at a
specific level, choose Humidistat Mode, described be-
low.
Humidistat Mode
HUMIDISTAT MODE
ON/OFF >
In ON mode, unit will maintain the humidistat setpoint
(see below). Press
MENU SELECTION to toggle be-
tween ON and OFF. NOTE: When in Humidistat mode,
the unit will display HUMIDISTAT on the top line during
normal operation rather than JOB HOURS.
HUMIDISTAT
SETPOINT 00% >
Sets humidity level when unit is in Humidistat Mode.
Press
MENU SELECTION to change RH value. Each
press of the button increases the setting by 5% incre-
ments, cycling through 90%RH and starting again at
40%RH.
TEMP UNITS
C° >
Shows current temperature scale. Press
LECTION to select Fahrenheit or Centigrade scale.
LANGUAGE
ENGLISH >
Shows current display panel language. Press
SELECTION to select Spanish, German, French or Eng-
lish.
COIL TEMP
00°C
Displays the cold (evaporator) coil temperature.
SENSOR ID >
00000000
This function is not used on the BD2500.
COMPRSSR CURRENT
0.0 A
Shows compressor current draw in amps.
AT THE END OF THE JOB
To reduce the possibility of drips when moving the unit,
follow these additional steps to ensure that all water is
removed from the unit.
NOTICE: To ensure the condensate tank empties com-
pletely while purging, make sure the unit is positioned
horizontally on a flat surface.
07-01900C F413-230V AU 2014-03
Warranty 07-01921 DoC 07-00289
1. If the unit is in a defrost cycle, wait until the unit has
returned to normal operating mode before proceeding.
To check, review the control panel. The control panel will
show one of the following:
Defrost in progress:
Shutdown Sequence
Display mode when unit is in defrost and is powered
down by the user. Unit will complete the defrost cycle to
remove any built-up ice and then purge the pump. XX
indicates the minutes remaining on the defrost cycle.
Normal Display:
Wait until the control shows the normal display before
proceeding.
2. Gently rock the machine to ensure any water remain-
ing on interior surfaces falls into the sump area.
MENU SE-
3. Press the
complete, turn the unit off.
4. Remove the external drain hose, drain it carefully, coil
it and secure it with one of the Velcro straps provided on
the side of the unit.
MENU
5. Unplug power cord from power supply, coil neatly, coil
it and secure it with one of the Velcro straps provided on
the side of the unit. (see Fig. A).
TRANSPORTATION AND STORAGE
NOTICE: Handle the unit carefully. Do not drop, throw,
or place the unit where it could fall. Rough treatment can
damage this equipment and may create a hazardous
condition or void warranty.
• Do not expose the control panel to moisture, snow
• Protect from freezing.
• Store and transport securely to avoid any damaging
• Secure during transport to prevent sliding and pos-
MAINTENANCE SCHEDULE
WARNING! ELECTRIC SHOCK HAZARD. Unplug unit
before cleaning or servicing.
WARNING: Risk of dust and contaminants exposure.
Use of respirator mask and gloves is recommended. If
unit has been exposed to potentially dangerous contam-
inants, clean thoroughly and sanitize before reuse.