Reassemble in reverse order.
The dehumidifier is now ready
for use.
Annually
Have the pump system
inspected by the Dri-Eaz Service
Department (800-932-3030) or
by a qualified service center.
TRANSPORTATION
AND STORAGE
NOTICE: Handle the unit
carefully. Do not drop, throw, or
place the unit where it could fall.
Rough treatment can damage
this equipment and may create a
hazardous condition or void
warranty.
Do not expose the control
panel to moisture, snow or
rain when transporting in
uncovered vehicles such as
flatbed trucks.
Store and transport securely
to avoid any damaging
impact to internal parts.
CLEANING COILS AND
HEAT EXCHANGE
BLOCK
Warning! Unplug unit before
servicing.
To help keep the unit operating efficiently, keep the coils
and the air-to-air heat exchange block clean. Access
these components by removing the side and rear covers:
1. Unplug unit.
2. Unplug the power cord from the socket at the base of
the unit. Remove pump hose at quick-connect.
3. Remove HAF filter.
4. Remove both side covers A and B (unscrew two bolts
shown for each panel).
5. Remove back cover (unscrew the four bolts shown on
the back and the two bolts on the upper front panel).
6. Remove the heat exchange block.
Inspect the heat exchange block carefully. If necessary,
use compressed air to clear the channels of the block,
taking care not to damage the block.
NOTICE: The unit is fitted with sensitive electronic
sensors. Protect the sensors from impact and do not
expose them to water or cleaning solution.
07-01674K F410, F411
FIG. G: CLEANING
Air-to-air heat
exchange block.
Arrows printed on
the block indicate
correct orientation
for installation.
Condenser coil
Evaporator (cold) coil
Side cover A
8
Pump hose – thread up through
hole in bottom of rear hose
pocket before reinstalling cover.
Vacuum or use compressed air on both sides of the
upright (condenser) coil until it is clean. Take care not to
let the nozzle touch the fins; as this may damage the
fins. A coil cleaner product may be used on the
horizontal cold (evaporator) coil only. Follow instructions
on product label. Take care not to spray or wipe product
on or near any electrical components or sensors. To
clean the vertical (condenser) coil, contact Service for
instructions.
To reassemble, follow the above steps in reverse. Be
sure to reinstall heat exchange block in the original
orientation. When installing the rear cover, carefully
thread the pump hose through the hole in the back
pocket before putting the cover in place.
NOTICE: Rubber strips are attached to the outside
edges of the evaporator and condenser coils to
provide an airtight seal around the heat exchange
block. When reinstalling the block, make sure the
seals are in place and are not kinked or folded.
HAF filter
Side cover B
Rear cover
Dri-Eaz Products, Inc.