AUTOSETSIGNAGEID
C2CONNECTION
UART_CHECK
GETTEMPERATURE
GETHUMIDITY
SETVIDEOCROP
GETVIDEOCROP
LEN
LPE
LDC
LDI
LBE
Sets signage id
automatically.
For usage the
feature the
AdvancedVideoWall
profile item should be
enable.
Returns the
handshake result
between G6F and C2
devices
Starts the handshake
process between G6F
and C2 devices
Measure ambient
temperature using
temperature sensor
Measure relative
humidity using
humidity sensor
Crop input video with
given parameters and
show full screen.
Wideowall must
be disabled or cell
number must be zero
to activate this feature.
Set width or height as
0 to disable crop.
Get crop parameters
LED Bar PWM
Enable/Disable of the
given color
LED Bar PWM Period
value of the given
color
LED Bar PWM Duty
Cycle value of the
given color
LED Bar PWM
Division value of the
given color
LED Bar Enable/
Disable via GPIO
English - 53 -
no parameter
no parameter
no parameter
no parameter
no parameter
string (X-Y-W-H)
no parameter
str-int n (W, R, G, B) (0 - 1)
str-int n (W, R, G, B) (0 -
65535)
str-int n (W, R, G, B) (0 -
65535)
str-int n (W, R, G, B) (0 -
65535)
int n (0, 1)
#*
OR
#*AdvancedVideoWall profile item
is disabled.
#*FAILURE, wait to check C2
availability (process still not
finished)
OR
#*FAILURE, C2 is not READY
(handshake failed, C2 is not
available)
OR
#*SUCCESS, C2 is READY
(handshake is succeded)
#*C2 handshake process is started
#*TEM=...
OR
#*Temperature sensor is not
available
#*HUM=...
OR
#*Humidity sensor is not available
#*set x position to X, set y position
to Y, set width to W, set height to H
#*x position is X, y position is Y,
width is W, height is H
#*SUCCESS
#*FAILURE
#*SUCCESS
#*FAILURE
#*SUCCESS
#*FAILURE
#*SUCCESS
#*FAILURE
#*SUCCESS