Rev.0 17/05/2021
EN
Pag.38
Stove phase general layout
PHASE
FINAL CLEANING
IGNITION
FLAME LIGHT
WORK
MODULATION
FIRE POT CLEANING
ECO STOP
WAITING START / RESTART
IGNITION RESTART
HOT SMOKES
OFF
WAIT FOR PELLETS OUT OF
AUGER OVERFLOW
ALARM (generic)
Use and maintenance manual Phandheld Touch Radio
DESCRIPTION
The stove is in the switch off phase and the cooling phase has
not been completed yet.
The heater pre-heating phase has started and the pellets start to
fall into the grate.
The pellets ignite and take advantage of the heat in the intake air
that passes through the incandescent heater tube.
The stove has completed the switch on phase and runs at
maximum set power
The room temperature set has been reached.
Fire pot cleaning phase is active (periodic function).
With Climate Comfort active, the stove switches to automatic
switch-off mode when the room temperature set is reached (see
the dedicated section).
Switch-on is requested but with the stove in cooling phase; once
this condition is met, it restarts automatically.
The HOT restart phase is activated.
Functioning is similar to the SWITCH ON phase
The maximum fume temperature threshold has been reached.
To facilitate cooling, the stove brings the capacity to a minimum
with ventilation at power level 5, leading to a decrease in fume
temperature.
The stove is off
When the switch-on request from ECO-STOP mode coincides
with an automatic switch-off condition (from the TIMER), the
stove turns on ensuring total cleaning of the fire pot before
switching to FINAL CLEANING.
CONDITION: when the pellet setting (set pellets +5) is near the
continuous load condition.
SOLUTION: Set the value back to 0.
The stove is in alarm state; refer to the troubleshooting chapter.