2. Provide an adequate gas
supply.
Please note: Operation at elevations above 2000
ft., appliance rating shall be reduced at the rate of 4
percent for each 1000 ft. above sea level.
This appliance is pre-set to operate on 4" natural
gas manifold pressure. A convertible pressure
regulator is connected to the manifold and MUST
be connected in series with the gas supply line. If
the LP/Propane conversion kit has been used, follow
instructions provided with the kit for converting the
pressure regulator to LP/Propane use.
Care must be taken during installation of range not
to obstruct the flow of combustion and ventilation
air.
For proper operation, the maximum inlet pressure
to the regulator should be no more than 14 inches
of water column pressure. The inlet pressure to
the regulator must be at least 1 inch greater than
regulator manifold pressure.
Example: If regulator is set for natural gas 4 inch
manifold pressure, inlet pressure must be at least
5 inches; if regulator has been converted for LP/
Propane gas 10 inch manifold pressure, inlet
pressure must be at least 11 inches.
Leak testing of the appliance shall be conducted
according to the instructions in step 4g.
The gas supply line should be 1/2" or 3/4" I.D.
3. Seal wall openings.
Seal any openings in the wall behind the range and
in the floor under the range after gas supply line is
installed.
4.Connect range to gas supply.
Note: To prevent leaks use pipe joint sealant on
all male (outside) pipe threads. Do not allow gas
pressure regulator to turn on pipe when tightening
fittings.
a. Install an external manual gas shut-off valve to
gas supply line in an accessible location outside
of range. Be sure you know where and how to
shut off the gas supply to the range (See Fig. 8).
b. Install 1/2" flare union adapter to gas pressure
regulator using no more than 15ft./lbs. of
torque (Refer to Fig. 8).
Pressure
regulator
Flare
union
adaptor
Fig. 8 - gas supply connections
Be sure to stabilize the left side of the gas
pressure regulator before tightening ANY fittings
to the pressure regulator. Do not allow pressure
regulator to turn on pipe when tightening fittings
(Refer to Fig. 9).
Flexible appliance
conduit
Flare
union
adaptor
shut-off
Fig. 9
Manual
valve
9