Meter Operation

Voltage and Polarity

First, turn the meter on by pressing the ON/OFF Button and then
insert into an outlet. If the batteries are good, the 61-517 will beep
continuously to indicate live voltage, display the correct voltage,
and indicate 3 bright green LEDS on the top and the bottom IF the
HOT NEUTRAL and GROUND polarity of the outlet is correct. After
removing the 61-517 from an outlet it will continue to display the
polarity LED's and measured voltage value for 5 seconds and shut off
after 3 minutes of inactivity. This gives the user time to unplug from
hard to reach or limited access outlets such as those behind furniture
and still have a clear indication of the outlets condition.
If any other polarity condition is encountered other than correct
H-N-G, one or more red lights will illuminate. Refer to the legend to
identify the incorrect wiring condition.
See table on page
13
for all conditions the 61-517 can detect.
NOTE: The 61-517 will automatically turn itself on when inserted into
a live outlet.