Spoon
Main Cable
Stop Sleeve
Cleaning Bushing
1.5" (38mm)
7.0" (178mm)
End Termination
Heavy Duty Return Wire
PERFORMANCE:
Static Tensile Strength: 10,000-lbf (44kN)
Maximum Capacity: one worker with
max weight of 310-lbs when used as a
single point anchorage connector for per-
sonal fall arrest or restraint system.
DIMENSIONS:
Weight: 1-lbs (476g)
Length: 13.75" (349mm)
Diameter 1" (25mm)
DRILLING & INSTALLATION INSTRUCTIONS:
1. Drill a 1" (25mm) diameter hole at least 4.5" (114mm) deep. The drilled hole must be straight and perpendicular to
the surface. Make sure the hole is of uniform diameter and free of peaks and valleys on the inner wall.
2. Blow hole clean with compressed air.
3. Always inspect the hole carefully when reusing a previously drilled hole.
4.
ngers and thumb together till the trigger and spring fully compress.
5. Insert unit at least 4" (101mm) deep into hole and release the trigger. Do not force.
6. Set the unit with a slight tug on the anchor loop.
7. The stop sleeve must always be partially inserted into the hole.
drill
Spring
Swage
Anchor Loop
13.75" (349mm)
3.0" (76mm)
Trigger
REGULATORY COMPLIANCE:
ANSI Z359.1-2007, ANSI Z359.7-2011
OSHA 1926.502, OSHA 1910.66,
EN 795:2012 Class A
COMPONENT MATERIALS:
Aluminum: Trigger
Aircraft Cable: Main Cable, Activator Wire
Polyurethane: Loop Cover
Stainless Steel: Cone, Spoons, Stop Sleeve
Zinc Plated Steel: Spring
Zinc Plated Copper: Swage
ngers around the trigger.
10"
1"
Ø
REMOVAL INSTRUCTIONS:
1. When removing anchor, place your thumb inside the anchor loop
thumb together till the trigger and spring fully compress.
2. While squeezing the trigger pull the anchor out of the hole.
3. If the anchor becomes stuck, insert a punch, screwdriver or other
object into the hole until it touches the top of the cleaning bushing.
4. Lightly tap with a hammer making sure the tool is touching the top
2" (50.8mm)
of the cleaning bushing while squeezing the trigger. (The cleaning
bushing should be easily visible at the edge of the hole).
5. If tool was required to remove the anchor inspect thoroughly for
damage after removal. If damage is found remove from service and
destroy immediately.
DO NOT REMOVE
10"
WARNING LABEL!
Compliance: OSHA 1926.502 & 1910.66 / ANSI Z359.1, ANSI Z359.7
EN 795:2012 Class A
WARNING!!!
ALL PERSONS USING THIS EQUIPMENT MUST READ AND UNDERSTAND ALL INSTRUCTIONS.
FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH. USERS SHOULD BE FAMILIAR
WITH PERTINENT REGULATIONS GOVERNING THIS EQUIPMENT. ALL INDIVIDUALS WHO USE
THIS PRODUCT MUST BE PROPERLY INSTRUCTED ON HOW TO USE THIS DEVICE.
Stainless Steel, Aluminum, Zinc Plated Copper, 7x19 Aircraft Cable
Pat# US 7,357,363 B2 / US7,011,281 B2 / US 6,729,821 B2
May be used as a anchoring point for a leading edge
restraint system. Examples are of optional anchor-
ing point locations. The use of two anchors is not
ngers and
required for leading edge restraint systems unless
ed by the manufacturer.
*The user shall be equipped with
a means of limiting the maximum
dynamic forces exerted on the
user during the arrest of a fall to a
maximum of 6 kN (1350-lbf )
WORK SURFACE
MINIMUM CLEARANCE 3ft (1m)
DECK/FLOOR/GROUND LEVEL
All products subjected to fall arresting forces should be removed
Removable Concrete Anchor
Model: A510010
from service immediately!
1-(888)-523-3371
Max Capacity 310-lbs
OPTIONAL
(ANCHOR POINTS)
WORK SURFACE
(ANCHOR POINT)
The concrete must be
3000-psi or higher and
fully cured. Installation
location to be approved
ed person.