TROUBLESHOOTING

PROBLEM
POSSIBLE
CAUSE
The motor does
The power switch
not start.
is off.
You do not plug
the power cord.
Electrical outlet
does not supply
sufficient power.
The circuit breaker
is tripped.
The power switch
is on, but you do
not pull the gun
trigger.
The machine does
The diameter of
not get high pres-
garden hose is too
sure.
small.
The garden hose is
blocked.
The water supply
is not sufficient.
You do not install
the nozzle onto the
spray wand.
The water intake
filter is blocked.
English
PROBLEM
SOLUTION
Set the power
switch to the
"ON" ( | ) posi-
tion.
Connect the power
cord to the power
supply.
Try another elec-
trical outlet.
The output pres-
Let it cool, and
sure varies high
start the machine
and low.
again.
Pull the gun trig-
ger.
Replace with a 1"
(25 mm) or 5/8"
(16 mm) garden
hose.
Make sure that the
garden hose is free
from blockage.
Open the water
suppy fully.
Install the nozzle
onto the spray
wand.
Remove the filter
and make it clean
in warm water.
7
POSSIBLE
SOLUTION
CAUSE
The water supply
Open water suppy
is not sufficient.
fully. Make sure
the garden hose is
free from block-
age.
The pump absorbs
1. Make sure that
air.
the hoses and
fittings have
no problem.
2. Turn the ma-
chine off.
3. Pull the gun
trigger until a
stable flow of
water comes
out through
the nozzle.
The water intake
Remove the filter
filter is clogged.
and clean it in
warm water.
The supply volt-
Make sure that on-
age is low.
ly the pressure
washer operates
on the circuit.
The gun, hose or
Operate distilled
nozzle are calci-
vinegar through
fied.
detergent tank.