Function F3 - Register/de-register additional digital controller (maximal 3 Controller), see f old-out page IV, Fig. [20].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F3 Function select by turning the ring
• Start F3 - Register additional digital controller
=> Confirm by simultaneously pressing the - / + buttons.
- Press the buttons 1 + 3 of the additional digital controller simultaneously in order to
register it.
- Pressing the - / + buttons simultaneously on the pending digital controller saves the
selection and exits the menu.
• Start F3 - De-register additional digital controller
=> Confirm by simultaneously pressing the - / + buttons.
- Pressing the - / + buttons simultaneously on the factory digital controller to de-
register all additional controllers.
Abort the function menu by pressing and holding Start/Stop button or after 3 minutes
without triggering.
Function F4 - Factory reset, see f old-out page IV, Fig. [20].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F4 Function select by turning the ring
• Start F4 - Factory reset
=> Confirm by simultaneously pressing the - / + buttons.
- Press + button of digital controller.
- Press - button of digital controller.
- Press Start/Stop button of digital controller.
=> Confirm by simultaneously pressing the - / + buttons.
False entry => abort menu.
Abort the function menu by pressing and holding Start/Stop button or after 3 minutes
without triggering.
Function F5 - Activate continuous operation, see fold-out page IV, Fig. [20].
Button Description
Start the function menu
- Select the function by simultaneously pressing and holding the - / + buttons.
- F5 Function select by turning the ring
• Start F5 - Activate continuous operation
=> Confirm by simultaneously pressing the - / + buttons.
- Press Start/Stop button of digital controller.
- Press - button of digital controller.
- Press + button of digital controller.
Pressing the - / + buttons simultaneously starts the continuous operation.
=>
False entry => abort menu.
Caution: Risk of scalding.
Abort of the function after 15 minutes (after that cold water runs for a minute) or
prematurely by operating the digital controller as well as a the transceiver (no cold
water running).
Maintenance
Inspect and clean all components and replace if necessary.
Disconnect voltage supply.
Disconnect all plug-in connectors.
Shut off hot and cold water supply.
I. Change digital controller batteries, see fold-out page IV, Fig. [22] and
fold-out page III, Figs. [7] to [11].
Insert batteries with correct polarity.
II. Change functional unit battery, see fold-out page IV, Figs. [23]
and [24].
The battery must be replaced 10 years after commissioning the functional
unit, at the latest. Insert battery with correct polarity.
Assemble in reverse order. Approx. 10 seconds after the voltage supply is
established there are two brief water pulses and the buttons of the digital
controller are now inoperative for 60 seconds.
III. Remove and clean flow regulator (13 220), see fold-out-page IV,
Fig. [25]. Assembly in reverse order.
Please pass these instructions on to the end user of the fitting.
3
The right to make technical modifications is reserved.
English
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes green 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 1x.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 4x.
Illuminated ring flashes green 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Illuminated ring flashes green 3x.
Illuminated ring flashes violet 3x.
Illuminated ring flashes violet 1x.
Visualization
Illuminated ring flashes red 1x.
Illuminated ring flashes red 5x.
Illuminated ring flashes green 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Segment of illuminated ring flashes blue 1x.
Illuminated ring flashes cyan 3x.
Illuminated ring flashes violet 3x.
Illuminated ring flashes cyan 3x.
Service
In the event of problems with installation, please switch off the voltage
supply and consult a specialist installer or the GROHE Service Hotline via
email at TechnicalSupport-HQ@grohe.com.
Replacement parts
See fold-out page I (* = special accessories).
Disposal instructions
This category of device does not belong in the domestic waste,
but must be disposed of separately in accordance with the
relevant local national regulations.
Dispose of batteries in accordance with national regulations.