Maintenance
Shut off hot and cold water supply.
Inspect, clean and, if necessary, replace parts.
I. Battery
Batteries which are almost discharged are indicated by a
flashing indicator lamp.
1. Fit cleaning clip (K), see Fig. [7].
2. Remove screw (L) and detach housing (M), see Fig. [8].
3. Detach protective sleeve (N) and remove battery(O), check
contacts, clean and if necessary replace.
Assemble in reverse order.
II. Solenoid valve
1. Proceed as for maintenance of battery, points 1 to 3.
2. Remove screws (P1) and detach battery tray (P),
see Fig. [9].
3. Detach plug-in connection (R) and remove solenoid
valve (S) by turning clockwise using a 5mm allen key,
see Fig. [10].
4. Remove filter (T).
Install in the reverse order observing the installation position.
III. filter
1. Unscrew connection hose and remove adapter (C),
see Fig. [11].
2. Remove filter (B).
Assemble in reverse order.
Fault/ Cause/ Remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve without
contact
• Battery discharged
• Hands not in reception range
Indicator lamp
• Battery almost discharged
flashing
Water flowing
• Solenoid valve defective
continuously
Undesired water flow
• Sensor system detection zone set too high
for local conditions
Flow rate too low
• Filter or mousseur dirty
• Service valves not fully open
• Water supply restricted
Mixing device
• See "Flow rate too low"
incorrect
• Limescale on mixer spindle
• Temperature limiter incorrectly set
For latest prices and delivery to your door visit MyTub Ltd - 0845 303 8383 - www.mytub.co.uk - info@mytub.co.uk
IV. Remove mousseur (13 220) using a spanner and clean
Assemble in reverse order.
V. Mixer spindle
1. Disconnect fitting from connections.
2. Remove fitting from wash basin. Disassembly is as
described in section "Setting temperature limiter",
see Figs. [5] and [6].
3. Remove screw (U) from housing using a 2.5mm allen key,
see Fig.[12].
4. Pull out mixer spindle (G).
Assemble in reverse order.
Screw (U) must engage in groove (G1) of mixer
spindle (G).
Replacement parts, see fold-out page I (* = special
accessory)
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Disposal note
Dispose of batteries in accordance with national
regulations!
Remedy
- Open shut-off valves, service valves
- Clean, see Maintenance, Solenoid valve
- Replace, see Maintenance, Solenoid valve
- Attach plug-in connector
- Replace, see Maintenance, Battery
- Hold hands directly under the spout
- Replace, see Maintenance, Battery
- Replace, see Maintenance, Solenoid valve
- Reduce range using remote control (special
accessory, Prod. no.: 36 206)
- Replace, see Maintenance, Filter and Mousseur
- Fully open shut-off valves, service valves
- Check supply lines, open service valves
- Clean, see Maintenance, Mixer spindle
- Setting, see "Setting temperature limiter"