Stop Assembly
7. Reassemble the Valve
Solder Installations Only
Slowly open the water supply and flush the lines and valve body
before assembling the internal components. Turn off the water
supply.
Reinstall the stop assembly (certain models) and the pressure
balancing unit.
For reversed valves in back-to-back installations proceed to
"Back-to-Back Installations Only."
Reinstall the cap assembly with the black tab oriented up.
Install the collar and secure with the screws.
Back-to-Back Installations Only
The cap assembly for the reversed valve only will need to be
reinstalled, with the black tab oriented down, to the valve with
the reversed supply connections. Install the cap assembly to the
second valve with the black tab oriented up.
Install the collar and secure with the screws.
Kohler Co.
Pressure
Balancing Unit
Collar
13
Cap Assembly
Black Tab
1128093-2-E