Setting the mode
The set mode can be changed with the
to the following procedure:
For setting mode 1: Press the
x
H1P LED is off
. This mode is not available for heat recovery
units.
For setting mode 2: Press the
5 seconds, the H1P LED is on
c
If the H1P LED is blinking
and the
once, the setting mode will change to setting mode 1.
NOTE
If you get confused in the middle of the setting
process, push the
BS1 MODE
setting mode 1 (H1P LED is off).
Setting mode 2
The H1P LED is on.
Setting procedure
1
Push the
button according to the required function
BS2 SET
(A~H). The LED indication that matches the required function is
shown below in the field marked
Possible functions
A
additional refrigerant charging operation.
B
refrigerant recovery operation/vacuuming operation.
C
automatic low noise operation setting at nighttime.
D
low noise operation level setting (
control adapter.
E
power consumption limitation setting (
control adapter.
F
enabling function of the low noise operation level setting
(
L.N.O.P
) and/or power consumption limitation setting
(
) via the external control adapter (DTA104A61/62).
DEMAND
G
high static pressure setting
H
evaporating temperature setting
H1P H2P H3P H4P H5P H6P H7P
w x w x w x x
A
w x w x w x w
B
w x w x w w x
C
w x w w x x w
D
w x w w w w x
E
w x x w w x x
F
w x w x x w x
G
w x x w x x x
H
2
When the
button is pushed, the current setting is
BS3 RETURN
defined.
3
Push the
button according to the required setting
BS2 SET
possibility as shown below in the field marked
3.1 Possible settings for function A, B, F, and G are
(OFF).
H1P H2P H3P H4P H5P H6P H7P
w x x x x c x
ON
(a)
w x x x x x c
OFF
(a) This setting = factory setting
U-8~16ME4XPQM
Urban Multi air conditioner
4PW40728-1
button according
BS1 MODE
button once, the
BS1 MODE
button for
BS1 MODE
w
.
button is pushed
BS1 MODE
button. Then it returns to
:
L.N.O.P
) via the external
DEMAND
) via the external
.
(ON) or
ON
OFF
3.2 Possible settings for function C
The noise of level 3 < level 2 < level 1 (
H1P H2P H3P H4P H5P H6P H7P
(a)
w x x x x x x
OFF
w x x x x x c
1
w x x x x c x
2
w x x x x c c
3
(a) This setting = factory setting
3.3 Possible settings for function D and E
For function D
only: the noise of level 3 < level 2
(
)
L.N.O.P
< level 1 (
1
).
For function E
(
DEMAND
level 1< level 2 < level 3 (
H1P H2P H3P H4P H5P H6P H7P
w x x x x x c
1
w x x x x c x
(a)
2
w x x x c x x
3
(a) This setting = factory setting
3.4 Possible settings for function H
The evaporating temperature level H (high) < level M (medium)
L
< level L (low) (
).
H1P H2P H3P H4P H5P H6P H7P
w x x x x x c
H
w x x x x c x
(a)
M
w x c x x x x
L
(a) This setting = factory setting
4
Push the
button and the setting is defined.
BS3 RETURN
5
When the
button is pushed again, the operation
BS3 RETURN
starts according to the setting.
Refer to the service manual for more details and for other settings.
Confirmation of the set mode
The following items can be confirmed by setting mode 1 (H1P
LED is off)
Check the LED indication in the field marked
1
Indication of the present operation state
x
-
, normal
w
-
, abnormal
c
-
, under preparation or under test operation
H1P H2P H3P H4P H5P H6P H7P
x x w x x x x
2
Indication of low noise operation state
x
-
standard operation (= factory setting)
w
-
operation
L.N.O.P
H1P H2P H3P H4P H5P H6P H7P
x x w x x x x
3
Indication of power consumption limitation setting
x
-
standard operation (= factory setting)
w
-
operation
DEMAND
H1P H2P H3P H4P H5P H6P H7P
x x w x x x x
1
).
only: the power consumption of
)
3
).
.
L.N.O.P
DEMAND
Installation manual
24