x900 Series Switch and SwitchBlade
PWR05
The following table describes LEDs on the PWR05 (AC) power supply unit for
the SwitchBlade x908.
LEDs
LED
~
22
®
x908
State
Description
Green
AC input voltage is within 90-264VAC, 47-63Hz.
Off
AC input voltage is outside the acceptable range.
Green
DC output voltage is within 12V +/- 10%.
Off
DC output voltage is outside the acceptable range.
Red
A fault has occurred. There is either a fan failure, or the
temperature has exceeded its limit of 70ºC (158ºF).
Off
No fault conditions detected.