DESCRIPTION
KNOW YOUR CHARGER (Fig. A)
1.
Power Cord
2.
Output Interface
3.
Button
4.
1# LED (Green)
5.
2# LED (Green)
6.
3# LED (Red)
7.
Input Interface
8.
Wall Mounting Hole
9.
Cooling Air Port
OPERATION
HOW TO CHARGE THE BATTERY PACK
WARNING:
Do not use the charger outdoors or expose
it to wet or damp conditions. Water entering the charger will
increase the risk of electric shock.
NOTICE:
Lithium-Ion battery packs are shipped partially
charged. Before using it the first time, fully charge the
battery pack.
1. Insert the separate power cord into the input
interface (Fig. B).
2. Connect the charger to the power supply
(220-240V/50Hz).
3. Insert the battery plug into the charger as Fig. C & D
shown.
4. The charger will communicate with the battery pack
to evaluate the condition of the battery pack.
5. When the battery pack is charging normally, the
green 1# LED on the charger will flash. If keep the
green button pressed for at least 1 second, the
normal charging will transform to rapid charging and
green 1# LED goes out with green 2# LED flashing.
The fan in the charger works continuously to cool the
battery pack.
6. When the battery pack is fully charged, the charging
indication LEDs stop blinking and will shine green
continuously. Wait until the cooling fan stops, remove
the battery pack from the charger and disconnect the
charger from the power supply.
7. The battery pack will fully charge if left on the
charger, but it will not overcharge.
NOTICE:
◾
While the charger is connected to a power supply
in step1, if the 3 LEDs still remain unlit,refer to
the section on "DEFECTIVE BATTERY PACK OR
CHARGER".
◾
A significantly reduced running time after fully
charging the battery pack indicates that the batteries
are near the end of their usable life and must be
replaced.
◾
The charger may warm during charging. This is part
of the normal operation of the charger. Charge in a
well-ventilated area.
56 VOLT CHARGER — CHX5500E
EN
5