Technical Data; Model Identification; Commissioning The Device; Operations Prior To Installation - Madas XVO/NC Serie Manual Del Usuario

Electroválvula automática normalmente cerrada para gas con apertura rápida
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

2.0 - TECHNICAL DATA

• Use
• Room temperature (TS)
• Power voltages (see table 3a-3b)
• Power supply tolerance
• Electric wiring
• N° cycles/hours (versions without energy saving) :
• N° cycles/hours (versions with energy saving)
• Absorbed power
• Maximum operating pressure
• Closing and/or opening time
• Protection rating
• Coil protection mode
• Class
• Mechanical resistance
• Rp threaded fittings
• NPT threaded fittings
• Filter element (on request)
• In compliance with
* Only single-phase, the device does not work if powered with three-phase voltage.

2.1 - MODEL IDENTIFICATION

XVO/NC
: Brass body
XVOF/NC
: Brass body + flow adjustment
XVOA/NC
: Aluminium body
XVOAF/NC : Aluminium body + flow adjustment ATEX 3G - 3D
2.2 - SIL LEVEL
The SIL level of the stand-alone solenoid valve is SIL 2; when two solenoids are installed in series and the relative seal test
(Valve Proving System), certified according to EN 1643, the achieved level is SIL 3, as set forth in EN 676:2008. The solenoid
valve has PL d level. For further data refer to the SIL LEVEL table (table 2).

3.0 - COMMISSIONING THE DEVICE

3.1 - OPERATIONS PRIOR TO INSTALLATION

All installation operations must be carried out in the absence of an explosive atmosphere.
• It is necessary to close the gas upstream of the valve prior to installation;
• Make sure that the line pressure DOES NOT EXCEED the maximum pressure declared on the product label;
• Any protective caps (if any) must be removed prior to installation;
• Valve pipes and insides must be clear of any foreign bodies;
• Make sure that the pipe thread is not too long, to prevent damaging the body of the device when screwing it on;
• In accordance with EN 161 a suitable filter must be installed upstream of a gas closing safety device;
• With outdoor installation, it is advisable to provide a protective roof to prevent rain from damaging the electrical parts of
the device.
• Prior to carrying out any electrical wiring operations, make sure that the main voltage matches the supply voltage indicated
on the product label;
XVO.../NC - XVOA.../NC
: non-aggressive gases of the three families (dry gases)
: -20 ÷ +60 °C (230 Vac with energy saving
: 12Vdc - 12 V/50 Hz - 24 Vdc - 24 V/50 Hz - 110 V/50-60 Hz - 230 V/50-60 Hz*
: -15% ... +10%
: electric cable l=3 metres with wire terminals
1800 (time ON 1s - time OFF 1s)
~
:
1000 (time ON 1s - time OFF 2,5s)
~
: see table 3a-3b
: 200 mbar
: <1 s
: IP65
: II 3G Ex mc ec nC IIC T4 Gc X - II 3D Ex mc tc IIIC T135°C Dc X
: A
: Group 2
: (DN 10 - DN 15 - DN 20) according to EN 10226
: request feasibility
: metal net with filtering surface ≤ 1mm
: Regulation (EU) 2016/426 (Appliances burning gaseous fuels)
EN 60079-0-7-14-15-18-31 - ATEX Directive 2014/34/EU
EMC Directive 2014/30/EU - LVD Directive 2014/35/EU - RoHS II Directive 2011/65/EU
ATEX 3G - 3D
ATEX 3G - 3D
ATEX 3G - 3D
10
Madas Technical Manual - 1|1.1X - REV. 1 of 6
-20 ÷ +85 °C)