GYS Tool it PBT 824 Manual De Usuario página 11

Ocultar thumbs Ver también para Tool it PBT 824:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
Translation of the original instructions
What is «test code»?
It allows you to retrieve the test data in the form of a computer table:
A. Insert the supplied CD into the computer's drive.
B. Open the table.
C. Scan the barcode of the ticket (previously printed) using a barcode reader, or enter the code
in the first cell of the table.
D. The test results are displayed.
3. Select YES or NO with the arrows to print the result and press «ENTER».
4. Press «ENTER» to return to the main menu.
24 V battery test
To test a 24 V battery composed of 2 12 V batteries wired in series, the tester performs two separate tests on each of the batteries.
1. Select «BATTERY TEST» from the main menu and select «BATTERY PACK. 24 V ».
2. Connect the negative and positive clamps to the ends of the 24V battery pack. Press OK to start the test.
3. The display shows «CONNECT BATTERY 1».
4. Connect the clamps to the first 12V battery.
5. Press
to select «REGULAR / STANDARD» or «START / STOP».
6. Press
the button to select the battery type. Press «ENTER» to confirm.
7. Press
to select the standard (EN, CCA, BCI, CA, MCA, JIS, DIN, IEC, SAE, GB)
8. Press
to enter the battery capacity (expressed in Ampere-hours «Ah»)
9. Confirm the ambient temperature above 0° (32°F) by pressing «ENTER».
10. Follow the same procedure for battery n°2. Then print the ticket with both results.
TEST OF THE ALTERNATOR CHARGING SYSTEM
1. Select «system test» in the main menu.
2. Ensure that all consumers are off, such as headlights, lights, air conditioning, radio etc. before starting the engine.
3. When the engine is running, one of the following 3 results is displayed :
Results displayed
Starting normal volts
Low starting voltage
No starting voltage detected
4. Press «ENTER» to begin the charging system test.
Result of the start voltage test
Examples
High starting voltage when the test is
performed with the engine at idle
Normal starting voltage when the test
is performed with the engine at idle
Low starting voltage when the test is
performed with the engine at idle
5. The tester will prompt to «TURN ON CONSUMERS AND PRESS ENTER». Turn on the heater to maximum (heat), full
beam lights and rear headlights. Do not switch on cyclic loads such as air conditioning or windscreen wipers.
6. When the test is done, run the engine at 2500 rpm for 15 seconds.
7. Press «ENTER», the undulation of the charging system is visible. One of the three test results is displayed:
PBT 824
Analysis
The voltage is normal. Press "ENTER" to perform load circuit test
The voltage is below the limit. Tune the starter in line with the proce-
dure supplied by the manufacturer.
The starting voltage is not detected. Start the engine again.
Results displayed
ALT. IDLE VOLTS
xx.xx V HIGH
ALT. IDLE VOLTS
xx.xx V NORMAL
ALT. IDLE VOLTS
xx.xx V LOW
Analysis
Check that the connections are good. If every-
thing is properly connected, replace the regulator.
No problem detected. Normal operation of the
alternator.
The alternator does not provide enough power
to the battery. Check the belts, and ensure that
the alternator is running when the engine is
on. If the belts slip or are broken, replace them
and re-test. Check the connection between the
alternator and the battery. If the connection is
bad, clean or replace the cable and re-test. If
the alternator belts and connection are in good
condition, replace the alternator.
EN
11

Publicidad

Tabla de contenido
loading

Tabla de contenido