CleanShot
TM
2050 PSI Pressure Washer
CleanShot
2.
Pull trigger on spray gun and hold.
3.
When water supply is steady and constant, engage
safety latch.
To remove contaminants from the pump, follow
these steps:
I.
Set up pressure washer as described in"Preparing
PressureWasher For Use". Connect water supply and
turn
water
on.
2.
Remove
nozzle
extension
from
spray gun.
3.
Start
engine
according
to instructions
in"HowTo
Use
Your
Pressure
Washer".
4.
Squeeze
trigger on spray gun and hold.
5.
When water supply is steady and constant, engage
safety latch and refasten nozzle extension.
Check
In-Line
Filter
Refer to Figure I I and service the in-line filter if it
becomes dogged, as fottows:
I.
2.
iB_l_lrl1_g_
m_ i_l'_'_r_
.
4.
O-tin
Detach spray gun and nozzle extension from high
pressure hose. Detach nozzle extension from spray
gun and remove o-ring and screen from nozzle
extension. Flush screen, spray gun, and adjustable
nozzle extension with clean water to clear debris.
Placein-line filter screen into threaded end of nozzle
extension. Direction does not matter. Push screen in
with eraser end of pencil until it rests flat at bottom of
opening.Take care not to bend the screen.
Placeo-ring into recess. Pusho-ring snugly against in-
line filter screen.
Assemble nozzle extension to spray gun, as described
earlier in manual.
Nozzle
Maintenance
A pulsing sensation felt while squeezing the spray gun
trigger may be caused by excessive pump pressure.The
principal cause of excessive pump pressure is a nozzle
clogged or restricted with foreign materials, such as dirt,
etc.To correct the problem, immediately clean the orifice
following these instructions:
I.
Shut off engine and turn off water supply.
2.
Remove orifice from end of nozzle extension. Separate
nozzle extension from spray gun.Twist nozzle
clockwise to stream position. Using a 2mm (5/64) allen
wrench, remove orifice from end of nozzle extension
(Figure 12).
Orifice
3.
Remove in-line filter from other end of nozzle
extension.
4.
5.
Use a small paper clip to free any foreign material
clogging or restricting orifice (Figure 12).
Using a garden hose, remove additional debris by back
flushing water through nozzle extension (Figure 13).
Back flush between 30 to 60 seconds.Turn adjustable
nozzle extension to stream spray and move nozzle
from low to high while flushing.
/
12