Electrical and Environmental Specifications:
Table 1. Electrical Ratings
Operational Voltage
Flashes/Minute
Maximum Operating Current, mA
Frequency, Hz
DC in-rush current is 1.75 A @ 24VDC for 5 msec.
AC in-rush current is 2.0 A @ 85 VAC and 1.5 A @ 265 VAC for .25 msec.
Table 2. Ambient and Operating Temperature Ratings
Hazardous Locations
Class I, Div 2,
Groups A, B, C, and D
Class II, Div 2,
Groups F and G
Class III
Installation Environmental Ratings:
•
Ambient Storage Rating: -55°C to +70°C
•
Ambient Operating Rating: -50°C to +66°C
•
Type 4X (water tight and corrosion resistant) and indoor/outdoor use
•
IP66 (dust-tight and protection against heavy seas) and outside type (saltwater)
24 V DC/AC
60
380 mA
DC/50/60
Temperature Code or Maximum Temperature, °C
40°C Ambient
24 V
100 - 265 VAC
T6
T6
T6
T6
T6
T6
100 - 265 VAC
60
210 mA
50/60
55°C Ambient
24 V
100 - 265 VAC
T5
T5
T6
T6
T6
T6
-6-
66°C Ambient
24 V
100 - 265 VAC
T4A
T4A
T6
T6
T6
T6