ATTENTION!!!
BEFORE CONNECTING THE MACHINE
MAKE SURE THAT THE PLATE IS IN POSITION
ACCORDING TO THE DRAWING.
AFTER CONNECTING THE MACHINE AND TURNING THE
POWER ON, THE PLATE WILL AUTOMATICALLY LIFT.
IF IT DOES NOT, THIS MEANS THAT THE WIRING OF THE
PHASES IS INVERTED AND THE POSITION OF THE
WIRING SITUATED AT THE MACHINE'S INPUT WILL HAVE
TO BE CHANGED.
Inserting a circuit breaker and differential switch between the wiring and the mains is COMPULSORY.
The sensitivity of the differential must be 300 mA. Higher sensitivity, for example 30 mA, common in
domestic installations may cause operating anomalies in the machine.
Connect the three phases, neutral in the general switch and the protection cable to earth on the electrical
components panel according to the following table (section in mm
Correct earthing is essential to guarantee the safety of users and correct operation.
Voltage and Standard Wiring
Frequency
Cable Section 400 III+N+T / Fuse
Cable Section 230 III+T / Fuse
* To work at 60 Hz the Z40 driven pinion has to be replaced by a Z48 pinion.
Terminal box for the motor.
400V 3 +
24
PM-1025
400 III+N+T
Hz
50 / 60*
2
No. x mm
/ A
5X1.5 / 10
2
No. x mm
/ A
4x2.5 / 16
230V 3 +
2
).
Ø250
PM-1225
PM-1425
400 III+N+T
400 III+N+T
50 / 60*
5X1.5 / 10
5X1.5 / 16
4x4 / 20
4x4 / 20
50 / 60*