Make Electrical Connections For In-Line Blower Motor System - KitchenAid KVWC956KSS0 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Install In-line Blower System
NOTE: The blower motor housing can be mounted using four
holes from either the inlet side or the outlet side of the blower.
A
A
A
A. Mounting holes
1. Position the in-line blower motor housing in its mounting
location and mark the four mounting hole locations.
2. Drill four mounting pilot holes using a 3/16" (4.8 mm) drill bit.
3. Attach the in-line blower motor housing to the mounting
location with four 6 x 80 mm mounting screws and washers.
4. If it is removed, reinstall the blower motor assembly and
secure it with the screws previously removed.
5. If it is removed, reattach the motor electrical plug to the
connector on the blower motor assembly.
Complete Preparation
1. Determine and make all necessary cuts for the vent system.
IMPORTANT: When cutting or drilling into the ceiling or wall,
do not damage electrical wiring or other hidden utilities.
2. Determine the location where the 1/2" (1.3 cm) wiring conduit
will be routed through the ceiling or wall between the in-line
blower and the range hood.
1
3. Drill a 1
/
" (3.2 cm) hole at this location.
4
4. Locate the electrical terminal boxes in the in-line blower
housing and range hood. Remove the terminal box covers
and set the covers and screws aside.
B
A
A. Electrical terminal box
B. Electrical knockout
5. Remove the electrical knockout from the in-line blower
6. With the range hood mounted (see the "Install Range Hood"
A
7. Run the six 18 AWG wires through the 1/2" (1.3 cm) wiring
8. Install the conduit connectors and conduit to the in-line
A
9. Connect the vent system to the range hood and in-line
A
Electrical Connection Inside In-line Blower System
1. Disconnect power.
2. Connect the wires from the wiring conduit to the wires from
3. Use UL listed wire connectors and connect the black wires
4. Use UL listed wire connectors and connect the white wires
housing and range hood to prepare for the installation of the
UL listed or CSA approved 1/2" (1.3 cm) wiring conduit and
conduit connector.
section), run the 1/2" (1.3 cm) wiring conduit between the
inline blower motor housing and the range hood. Pull enough
1/2" (1.3 cm) wiring conduit to allow for easy connection to
the terminal boxes in the in-line blower housing and range
hood.
conduit and conduit connectors and into the terminal
boxes on the in-line blower housing and range hood. Leave
enough wire length in each terminal box to make the wiring
connections.
blower housing and range hood electrical terminal boxes.
blower system and seal all joints with clamps.
Make Electrical Connections for In-
Line Blower Motor System
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
the motor electrical plug cable inside the in-line blower
housing terminal box.
B
A
A. UL listed or CSA approved
1/2" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
(C) together.
(D) together.
C
D
E
F
G
H
I
F. Blue wires
G. Gray wires
H. Green (or yellow/green)
and green/yellow wires
I. Motor electrical plug cable