5. Use UL listed wire connectors and connect the red wires (E)
together.
6. Use UL listed wire connectors and connect the blue wires (F)
together.
7. Use UL listed wire connectors and connect the gray wires (G)
together.
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
8. Connect the green (or yellow/green) ground wire to the
green/yellow ground wire (H) in the terminal box using UL
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical Connection Inside Range Hood Between In-line
Blower System and Range Hood
1. With the range hood mounted (see the "Install Range Hood"
section), locate the wiring cable connector inside the range
hood.
2. Connect the 6-wire connector assembly supplied with the
in-line blower motor system to the mating cable connector
from the range hood.
3. Locate the terminal box inside the range hood and install
a 1/2" (1.3 cm) UL listed or CSA approved strain relief (see
"Complete Preparation" in the "Prepare Location" section).
4. Run the wire ends from the 6-wire connector assembly
through the 1/2" (1.3 cm) strain relief, leaving enough wire
length to make the wiring connections. Tighten the strain
relief screws.
5. Connect the wires from the six-wire connector assembly
to the wires from the wiring conduit inside the range hood
terminal box.
6. Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors (see the

"Make Electrical Power Supply Connection to Range Hood"

section).
12
B
A
A. UL listed or CSA approved
1/2" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
7. Go to "Make Electrical Power Supply Connection to Range
Hood" section.
Make Electrical Power Supply
Connection to Range Hood
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
1. Disconnect power.
2. Locate terminal box on top of the range hood.
A. Knockout in back of terminal box
B. Top of terminal box
C
D
E
F
G
H
I
F. Blue wires
G. Gray wires
H. Green (or yellow/green)
and green/yellow wires
I. Motor electrical plug cable