ART. 09/08535-00
Specifications
Function
Range &
Resolution
40,00 ACA
400.0 ACA
DC Current
1000 ACA
40,00 ACA
AC Current
400,0 ACA
1000 ACA
400,0 mVCC
4.000 VCC
DC Voltage
40,00 VCC
400,0 VCC
600 VCC
400.0 mVCA
4.000 VCA
AC Voltage
40,00 VCA
400,0 VCA
600 VCA
400,0 Ω
4.000KΩ
40,00KΩ
Resistance
400,0KΩ
4.000MΩ
40,00MΩ
40,00Nf
400,0nF
Capacitance
4.000μF
40,00μF
100,0μF
5.000Hz
50,00Hz
500,0Hz
Frequency
5.000kHz
50,00kHz
100,0kHz
0.5 to 99.0%
Duty Cycle
Pulse width: 100µs - 100ms, Frequency:
5.000Hz ~ 100.0kHz
Temp (type-K)
-20 to 1000 °C
(probe
-4 to 1832 °F
accuracy not
included)
Note: No Autoranging & 400mV AC Voltage Range
ELCART DISTRIBUTION SPA via Michelangelo Buonarroti, 46 - 20093 Cologno Monzese (Milano) ITALY
Tel. ++39 02.25117310 Fax ++39 02.25117610 sito internet: www.elcart.com
La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.
The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.
La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.
ELCART
servizio automatico documentazione tecnica
Accuracy (% of rea-
ding)
± (2.8% + 10 digits)
± (2.8 % + 5 digits)
± (3.0 % + 5 digits)
± (3.0% + 10 digits)
± (3.0 % + 5 digits)
± (3.0 % + 5 digits)
± (0.8% + 3 digits)
± (1.5% + 3 digits)
± (2.0% + 3 digits)
± (0.8% + 20 digits)
± (1.8% + 5 digits)
± (2.5% + 5 digits)
± (1.0% + 4 digits)
± (1.5% + 2 digits)
± (2.5% + 3 digits)
± (3.5% + 5 digits)
± (5.0% reading + 100
digits)
± (3.0% reading + 5
digits)
± (3.5% reading + 5
digits)
± (5.0% reading + 5
digits)
± (1.5% reading + 5
digits)
± (1.2% reading + 2
digits)
Sensitivity: 10Vrms min.
± (1.2% reading + 2
digits)
±(3.0% reading + 5°C)
± (3.0% reading + 7°F)
Clamp size
Opening 1.2" (30mm) approx
Diode Test
Test current of 0.3mA typical; Open
circuit voltage 1.5V DC typical
Continuity Check
Threshold <100°; Test current < 1mA
Low Battery
"
Indication
Overrange Indication
"OL" is displayed
Measurements Rate
2 per second, nominal
Input Impedance
7,8MΩ (VDC and VAC)
Display
4000 counts LCD
AC Current
50/60Hz (AAC)
AC Voltage
50/60Hz (VAC)
bandwidth
Operating
14 to 122°F (-10 to 50°C)
Temperature
Storage Temperature
-14 to 140°F (-30 to 60°C)
Relative Humidity
90%(0°C to 30°C); 75%(30°C to
40°C); 45%(40°C to 50°C)
Altitude
Operating: 3000m; Storage 10,000m
Over voltage
Category III 600V
Battery
One "9V" Battery
Auto OFF
approx. 35 minutes
Dimensions/Weight
229x80x49mm/303g
Safety
For indoor use and in accordance with
Overvoltage Category II, Pollution
Degree 2. Category II includes local
level, appliance, portable equipment,
etc., with transient overvoltages less
than Overvoltage Cat. III
Operation
NOTICES: Read and understand all warning and precaution
statements listed in the safety section of this operation manual
prior to using this meter. Set the function select switch to the OFF
position when the meter is not in use.
DC/AC Current Measurements
WARNING: Ensure that the test leads are disconnected from the
meter before making current clamp measurements.
1. Set the Function switch to the 1000A or400A or 40A range. If
the range of the measured is not known, select the higher range
first then move to the lower range if necessary.
2. Select AC or DC with the MODE button.
3. Press the trigger to open jaw. Fully enclose one conductor to be
measured.
4. The clamp meter LCD will display the reading.
DC/AC Voltage Measurements
1. Insert the black test lead into the negative COM terminal and the
red test lead into the positive V terminal.
2. Set the function switch to the V position.
3. Select AC or DC with the MODE button.
4. Connect the test leads in parallel to the circuit under test.
5. Read the voltage measurement on the LCD display.
PAGINA 5 DI 9
" is displayed
e-mail: info@elcart.it