Detailed setting
[3]–1. CHANGE LANGUAGE setting
The language that appears on the dot display can be selected.
• Press the [
MENU] button to change the language.
1 English (GB), 2 German (D), 3 Spanish (E), 4 Russian (RU),
5 Italian (I), 6 French (F), 7 Swedish
[3]–2. Function limit
(1) Operation function limit setting (operation lock)
• To switch the setting, press the [
1 no1 : Operation lock setting is made on all buttons other than the
[
ON/OFF] button.
2 no2 : Operation lock setting is made on all buttons.
3 OFF (Initial setting value) : Operation lock setting is not made.
* To make the operation lock setting valid on the normal screen, it is necessary to
press buttons (Press and hold down the [CIR.WATER] and [
at the same time for two seconds.) on the normal screen after the above setting
is made.
(2) Operation mode skip setting
After setting is changed, the operation mode can not be changed within the changed
range.
• To switch the following settings, press the [
1 Heating mode
: Sets the use or non-use of the Heating mode.
2 Heating ECO mode
: Sets the use or non-use of the Heating ECO
mode.
3 Hot Water mode
: Sets the use or non-use of the Hot Water mode.
4 Anti-freeze mode
: Sets the use or non-use of the Anti-freeze
mode.
5 Cooling mode
: Sets the use or non-use of the Cooling mode.
6 OFF (Initial setting value) : Operation mode skip is not executed.
* When the setting, other than OFF, is made, the skip settings of the Heating,
Heating ECO, Hot Water, Anti-freeze, and Cooling modes are executed at the
same time.
* A mode that is not available on the unit to connect cannot be used even if the
setting is "AVAILABLE."
(3) Temperature range limit setting
After this setting is made, the temperature can be changed within the set range.
• To switch the setting, press the [
1 LIMIT TEMP HEATING MODE:
The temperature range can be changed on heating mode.
2 LIMIT TEMP HOT WATER MODE:
The temperature range can be changed on heating/hot water mode.
3 LIMIT TEMP ANTI-FREEZE MODE:
The temperature range can be changed on anti-freeze mode.
4 LIMIT TEMP COOLING MODE:
The temperature range can be changed on cooling mode.
5 OFF (Initial setting) : The temperature range limit is not active.
* When the setting, other than OFF, is made, the temperature range limit setting
on hot water, anti-freeze and cooling mode is made at the same time. However,
the range cannot be limited when the set temperature range has not changed.
• To increase or decrease the temperature, press the [
button.
• Settable range
Lower limit: 30 ~70 °C (87 ~158 °F)
Hot Water mode
:
Upper limit: 70 ~30 °C (158 ~ 87 °F)
Lower limit: 30 ~45 °C (87 ~113 °F)
Heating mode
:
Upper limit: 45 ~30 °C (113 ~ 87 °F)
Lower limit: 10 ~30 °C (50 ~ 87 °F)
Cooling mode
:
Upper limit: 30 ~10 °C (87 ~ 50 °F)
* The settable range varies depending on the unit to connect.
16
ON/OFF] button.
ON/OFF] buttons
ON/OFF] button.
ON/OFF] button.
TEMP.
or
[3]–3. Mode selection setting
(1) Remote controller main/sub setting
• To switch the setting, press the [
1 Main : The controller will be the main controller.
2 Sub : The controller will be the sub controller.
(2) Use of clock setting
• To switch the setting, press the [
1 ON : The clock function can be used.
2 OFF : The clock function cannot be used.
(3) Timer function setting
• To switch the setting, press the [
followings.).
1 WEEKLY TIMER (Initial setting value): The weekly timer can be used.
2 AUTO OFF TIMER : The auto off timer can be used.
3 SIMPLE TIMER
: The simple timer can be used.
4 TIMER MODE OFF : The timer mode cannot be used.
* When the use of clock setting is OFF, the "WEEKLY TIMER" cannot be used.
(4) Contact number setting for error situation
• To switch the setting, press the [
1 CALL OFF
: The set contact numbers are not displayed in case of error.
2 CALL **** *** **** : The set contact numbers are displayed in case of error.
CALL_
: The contact number can be set when the display is as
shown on the left.
• Setting the contact numbers
To set the contact numbers, follow the following procedures.
Move the flashing cursor to set numbers. Press the [
] button F to move the cursor to the right (left). Press the [
] button C to set the numbers.
or
(5) Temp off see. setting
• To switch the following settings, press the [
1 ON : The setback amount setting is displayed under the water temperature
initial setting mode.
2 OFF : The setback amount setting is not displayed under the water tempera-
ture initial setting mode.
[3]–4. Display change setting
(1) Temperature display °C/°F setting
• To switch the setting, press the [
1 °C: The temperature unit °C is used.
2 °F:
The temperature unit °F is used.
(2) Water temperature display setting
• To switch the setting, press the [
1 ON
: The water temperature is displayed.
2 OFF : The water temperature is not displayed.
]
ON/OFF] button D.
ON/OFF] button D.
ON/OFF] button D (Choose one of the
ON/OFF] button D.
TEMP.
or
CLOCK
ON/OFF] button D.
ON/OFF] button D.
ON/OFF] button D.