Dry Pick Up - Shop-Vac 16LT Serie Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TooL HoLDeR ASSemBLy
(not standard with all models)
18. With rear of unit facing you,
6
take tool holder and position
it with tabs facing rear of
unit (figure 6).

DRy pick up

inSTALLing foAm SLeeVe AnD ReuSABLe DRy fiLTeR
(not standard with all models)
WARning:
ALWAyS DiSconnecT THe pLug fRom THe WALL ouTLeT BefoRe RemoVing THe TAnk coVeR.
21. The foam sleeve and reusable dry filter may be used to pick up dust and dry material; you must install both to ensure proper filtration. If the vacuum has
been used to pick up liquids, the foam sleeve must be cleaned and dried before installing for dry pick up. (See Wet Pick Up Operation on how to clean foam
sleeve).
22. With tank cover in an upside down position, slide foam sleeve down over lid cage pulling until foam sleeve completely covers lid cage
9
(figure 9).
11
10
23. Center the reusable dry filter on lid cage (figure
12
12).
25. Be sure the opening of the inlet deflector is facing
14
the tank bottom. If it is not, remove inlet deflec-
tor from the deflector guide sliding in an upward
motion. noTe: Hose must be removed before inlet
deflector can be taken out. Reinstall being sure
the opening of the inlet deflector is facing the tank
bottom (figure 14).
noTe: Ensure that the mounting ring is completely secure and in position by pressing down firmly around the ring in several places. Be sure the reusable dry
disc filter completely covers the foam sleeve. Check to ensure that all edges of the reusable dry filter are secure under the mounting ring.
WARning:
KEEP FILTERS CLEAN. EFFICIENCY OF THE VACUUM IS LARGELY DEPENDENT ON THE FILTER. A CLOGGED FILTER CAN
CAUSE OVERHEATING AND POSSIBLY DAMAGE THE CLEANER. CHECK THE FILTER PERIODICALLY AND REPLACE AS REqUIRED.
Questions? Visit Shop-Vac
®
7
noTe: Bottom of foam sleeve must be positioned on the outside of groove around lid cage for the reusable dry filter
to fit properly (figure 10, 11).
at www.shopvac.com or call 1-888-822-4644
19. Place "J" shaped tabs into
the slots on cord wraps
(figure 7). Press down
until tabs snap into place.
24. Slide mounting ring down over filter until ring is po-
13
26. To clean the reusable dry filter:
15
20. Press down on center
8
of tool holder until tab
latches on bottom of lid
(figure 8).
sitioned against the ribs of the lid cage (figure 13).
The reusable dry filter should always be in position
over the foam sleeve for dry pick up.
a. Remove mounting ring and filter from lid cage
(figure 15).
b. Shake off excess dirt and dust or (depending on
the condition of the filter) rinse with water. DO
NOT MACHINE WASH OR DRY.
c. To clean foam sleeve refer to Wet Pick Up Opera-
tion in this manual.
d. Allow filters to dry completely before reinstalling.