Clearance  between  the  module  frames  and  structure  or  ground  is  required  to 
prevent  wiring  damage  and  allows  air  to  circulate  behind  the  module.  The 
recommended  assembling  clearance  between  each  module  installed  on  any 
mounting system is a minimum of 5 mm distance.  
 
Clearance  between  the  module  frame  and  roof  surface  is  required  to  prevent 
wiring  damage  and  to  enable  air  to  circulate  behind  the  module.  Therefore  a 
minimum of 50mm is required between the module frame and the roof surface. 
 
When installed on a roof, the module shall be mounted according to the local and 
regional building and fire safety regulations. In case the module is installed in a 
roof integrated PV‐System (BIPV), it shall be mounted over a watertight and fire‐
resistant underlayment rated for such application. 
 
For Performance 3 AC modules, in order to provide better access of connection 
for  AC  cables  into  the  microinverter,  Maxeon  recommends  the  following 
installation sequence:  
When the microinverter is in lower position, then it is recommended 
to install the modules from Left to Right. 
When the microinverter is in upper position, then it is recommended 
to install the modules from Right to Left.   
  
Modules mounting systems should only be installed on building that have been 
formally  considered  for  structural  integrity  and  confirmed  to  be  capable  of 
handling the additional weighted load of the modules and mounting systems, by 
a certified building specialist or engineer. 
 
AC Modules are only certified for use when their factory frames are fully intact. 
Do not remove or alter any module frame. Creating additional mounting holes 
may damage the module and reduce the strength of the frame.  
 
Modules may be mounted using the following methods only: 
1)
Pressure  Clamps  or  Clips: 
Mount  the  module  with 
the  clips  attached  to  the 
longer sides of the module. 
Refer  to  the  allowable 
ranges in Section 5.0 (Table 
1  ).  Installers  must  ensure 
the clamps are of sufficient 
strength  to  allow  for  the 
maximum  design  pressure 
of  the  module.  Clips  and  clamps  are  not  provided  by  Maxeon  Solar 
Technologies. Clamps that secure to the top of the frame must not deform 
the  top  flange.  Clamps  must  apply  force  collinear  with  the  'wall'  of  the 
module  frame  and  not  only  to  the  top  flange.  Clamps  shall  not  apply 
excessive  force  to  the  frame,  warp  the  top  flange,  or  contact  the  glass  ‐ 
these  practices  void  the  module  warranty  and  risk  frame  and  glass 
breakage. Figure 1a illustrates locations for top frame clamp force. Avoid 
clamping within 50mm of  module  corners to  reduce  risk of frame  corner 
deflection and glass breakage. When clamping to the module frame, torque 
shall  never  exceed  15  N.m  to  reduce  chances  of  frame  deformation.  A 
calibrated  torque  wrench  must  be  used.  Mounting  systems  should  be 
evaluated  for  compatibility  before  installing  specially  when  the  system  is 
not using Clamps or clips. Please contact Maxeon Solar Technologies for the 
approval of the use of non‐standard pressure clamps or clips where torque 
values are higher than otherwise stated. 
2)
End  Mount:  End  mounting  is  clipping/clamping  of  solar  modules  at  the 
corner of short side to the supporting rail. The end‐mounting rail and clips 
or clamps must be of sufficient strength to allow for the maximum design 
pressure of the module. Verify this capacity for both 1) clamps or clips and 
2) end mounting system vendor before installation.
 
5.3 Handling of Modules during Installation 
 
Never  lift  or  move  the  modules  using  cables  or  the  junction  box  under  any 
circumstances. Do not place modules face forward in direct contact with abrasive 
surfaces such as roofs, driveways, wooden pallets, railings, or walls etc. The front 
                                  ©2021 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice.     
Force must not deform
top frame flange or
glass may break
Force has
to be
applied in
line with
frame
wall
Figure 1a: Clamp Force Locations
 
surface of a module is sensitive to oils and abrasive surfaces, which may lead to 
scratches and irregular soiling.  
 
Be careful not to touch the micro‐inverter while unloading the Performance 3 AC 
modules, as the micro‐inverter height exceeds the module frame slightly.  
 
AC Modules are featured with antireflective coated glass and they are prone to 
visible  finger  print  marks  if  touched  on  the  front  glass  surface.  Maxeon  Solar 
Technologies recommends handing AC Modules with gloves (no leather gloves) 
or limiting touching of the front surface.  Any finger print marks resulting from 
installation will naturally disappear over time or can be reduced by following the 
washing guidelines in Section 6.0 below. Any module coverage (colored plastic 
tarps  or  similar)  during  installation  can  lead  to  permanent  front  glass 
discoloration and is not recommended. The use of vacuum lifting pads can cause 
permanent marks on the front glass.  
Shading incidence need to be avoided during PV system operation. The system is 
not supposed to be energized until the mounting scaffolding or railing have been 
removed from the roof. 
 
Systems should be disconnected in any cases of maintenance which can cause 
shading  (e.g.  chimney  sweeping,  any  roof  maintenance,  antenna/dish 
installations, etc.). 
 
6.0 Maintenance   
Maxeon Solar Technologies recommends visual inspection on a regular basis of 
AC  modules  for  safe  electrical  connections,  sound  mechanical  connection,  and 
free from corrosion. This visual inspection should be performed by trained and 
licensed  personnel.  The  standard  frequency  is  once  a  year  according  to 
environmental conditions.  
  
Periodic cleaning of AC Modules is recommended, but is not required. Periodic 
cleaning has resulted in improved module performance, especially in regions with 
low  levels  of  annual  precipitation  (less  than  46,3cm  (18,25  inches)).  Consult 
installer supplier about recommended cleaning schedules for your area. Do not 
clean or spray modules with water during normal operation (module glass surface 
is hot).  To clean a module, spray it with potable, non‐heated water. Normal water 
pressure  is  more  than  adequate,  but  pressurized  water  100  bar  (min  50  cm 
distance) may be used. Fingerprints, stains, or accumulations of dirt on the front 
surface  of  the  module  may  be  removed  as  follows:  rinse  the  area  and  wait  5 
minutes. Re‐wet the area and then use a soft sponge or seamless cloth to wipe 
the glass surface in a circular motion. Fingerprints typically can be removed with 
a  soft  cloth  or  sponge  and  water  after  wetting.  NEVER  use  harsh  cleaning 
materials such as scouring powder, steel wool, scrapers, blades, or other sharp 
 
instruments to
clean module glass. Use of such materials on the modules will void 
the product warranty.  
 
Shipping Position: 
 
Install Position: 
 
7.0 Troubleshooting 
Make sure to follow all safety precautions described in this installation manual. 
The microinverters are monitored by Enphase Enlighten system. If a module is 
 