Appendix (Supplementary Technical Information) - Maxeon SunPower MAX5 RES AC Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 46
found  to  not  produce  power  through  the  Enphase  Enlighten  System,  please 
contact  Enphase  as  the  first  point  in  the  trouble  shooting  process.  If  Enphase 
microinverter is found to be functioning properly, Enphase will contact Maxeon 
Technical Support directly. 
Troubleshooting  an  inoperative  microinverter,  please  follow  the  Enphase 
troubleshooting process: 
1. Web forms – send an email through https://enphase.com/en‐
in/support/contact‐support#form
  
2.  Call center 
Europe 
Netherlands: +31‐73‐7041633 
France/Belgium: +33(0)484350555
Germany: +49 761 887893‐20 
UK: +44 (0)1908 828928 
APAC 
Melbourne, Australia: +1800 006 374 
New Zealand: +09 887 0421 
India: +91‐80‐6117‐2500 
 
3. Claiming process through Enlighten for installers: 
https://enphase.com/en‐uk/support/system‐owners/troubleshooting 
 
All other faults please refer to the Enphase IQ Envoy Installation and Operation 
Manual at enphase.com/support for troubleshooting procedures. 
 
 
 
Table 2. Electrical Characteristics and Grid Interaction. 
 
DC Electrical Characteristics: 
 
 
Model 
SPR‐MAX5‐420‐E3‐AC 
SPR‐MAX5‐415‐E3‐AC 
SPR‐MAX5‐410‐E3‐AC 
SPR‐MAX5‐400‐E3‐AC 
SPR‐MAX5‐390‐E3‐AC 
SPR‐P3‐385‐BLK‐E‐AC 
SPR‐P3‐380‐BLK‐E‐AC 
SPR‐P3‐375‐BLK‐E‐AC 
SPR‐P3‐370‐BLK‐E‐AC 
AC Electrical Characteristics: 
 
 
AC Voltage 
Model 
Output 
(nom., V) 
SPR‐MAX5‐420‐E3‐AC 
219‐264  
SPR‐MAX5‐415‐E3‐AC 
219‐264 
SPR‐MAX5‐410‐E3‐AC 
219‐264 
SPR‐MAX5‐400‐E3‐AC 
219‐264
SPR‐MAX5‐390‐E3‐AC 
219‐264 
SPR‐P3‐385‐BLK‐E‐AC 
219‐264  
SPR‐P3‐380‐BLK‐E‐AC 
219‐264 
SPR‐P3‐375‐BLK‐E‐AC 
219‐264 
SPR‐P3‐370‐BLK‐E‐AC 
219‐264 
Please refer to the module datasheet for the AC electrical characteristic
                                  ©2021 Maxeon Solar Technologies, Ltd. All rights reserved. Specifications included in this document are subject to change without notice.     
DC values @ STC  
Curr. at 
Voltage at 
Nom. 
Power 
Rated 
Rated Power 
Power (W) 
Tol. (%) 
Power, Impp 
(Vmpp) 
(A) 
420 
+5/−0 
40.5 
10.4 
415 
+5/−0 
40.3 
10.3 
410 
+5/−0 
40.0 
10.2 
400 
+5/−0 
39.5 
10.1 
390 
+5/−0 
39.0 
9.99 
385 
+5/−0 
36.3 
10.61 
380 
+5/−0 
35.9 
10.59 
375 
+5/−0 
35.5 
10.57 
370 
+5/−0 
35.1 
10.55 
 
AC values @ STC 
AC Max. 
AC Max. 
Max. 
AC Peak 
Cont. 
Cont. 
Series 
Output 
Freq. (nom., 
Output 
Output 
Fuse 
Power 
Power, W 
Curr. (A) 
(A) 
(W) or VA 
or VA 
1.52 
20 
349 
366 
 
 
 
1.52 
20 
349
366
 
 
 
1.52 
20 
349
366
 
 
 
1.52 
20 
349
366
1.52 
20 
349 
366 
1.52 
20 
349 
366 
1.52 
20 
349 
366 
1.52 
20 
349 
366 
1.52 
20 
349 
366 
8.0 Appendix (Supplementary Technical Information) 
 
1. Enphase IQ7 Installation and Operation Manual 
https://enphase.com/en‐uk/support/enphase‐iq‐7‐iq‐7‐iq‐7x‐microinverter‐
installation‐and‐operation‐manual  
 
2. Enphase Installer Toolkit Commissioning: 
https://enphase.com/en‐in/support/gettingstarted/commission
 
Enphase Installer Toolkit is the mobile app where you can view the 
microinverter serial numbers and connect to the IQ Envoy to track system 
installation progress. To download, go to http://www.enphase.com/toolkit and 
log in to your Enlighten account. 
Getting Started Guide: 
https://enphase.com/sites/default/files/GettingStartedGuide_SystemVerificatio
nUsingInstallerToolkit_InsideSystem.pdf
 
Installation Troubleshooting : 
https://enphase.com/en‐uk/support‐associated‐products/installer‐
toolkit  
 
3. Enphase IQ Envoy Installation and Operation Manual: 
Refer to the Enphase IQ Envoy Installation and Operation Manual to activate the 
system monitoring and grid management functions. 
https://enphase.com/sites/default/files/downloads/support/IQ‐Envoy‐Manual‐
EN‐US.pdf
 
The guide provides the following: 
o
Connecting the Envoy 
o
Detecting devices and scanning the installation map 
o
Connecting to Enlighten and registering the system 
DC Ratings 
Voltage 
Open Circuit 
Curr. (Isc) 
Short Circuit 
(Voc) Temp. 
Voltage, Voc 
Temp. Coeff. 
Curr., Isc(A) 
(V) 
(%/°C) 
48.2 
10.9 
0.057 
−0.239 
48.2 
10.9 
0.057 
−0.239 
48.2 
10.9 
0.057 
−0.239 
48.1 
10.9 
0.057 
−0.239 
48.0 
10.8 
0.057 
−0.239 
43.7 
11.31 
0.06 
43.4 
11.28 
0.06 
43.0 
11.26 
0.06 
42.6 
11.24 
0.06 
Extended 
AC Short Circuit 
Frequency 
Fault Current 
Overvolta
Range 
Over 3 Cycles  
ge Class 
Hz) 
(Hz) 
(A rms) 
AC Port 
50 
45‐55 
5.8 
III 
 
50 
45‐55 
5.8
III 
 
50 
45‐55 
5.8
III 
 
50 
45‐55 
5.8
III 
50 
45‐55 
5.8 
III 
50 
45‐55 
5.8 
III 
50 
45‐55 
5.8 
III 
50 
45‐55 
5.8 
III 
50 
45‐55 
5.8 
III 
 
MAXEON SOLAR TECHNOLOGIES, LTD. 
Temperature  
Power Temp. 
NOCT @ 
Module 
Coeff. 
20°C (value ± 
Coeff. 
Efficiency (%) 
(%/°C) 
2°C) 
(%/°C) 
−0.29 
43 
22.5 
−0.29 
43 
22.3 
−0.29 
43 
22.0 
−0.29 
43 
21.5 
−0.29 
43 
20.9 
−0.28 
−0.34 
45 
19.6 
−0.28 
−0.34 
45 
19.4 
−0.28 
−0.34 
45 
19.1 
−0.28 
−0.34 
45 
18.9 
AC Ratings 
Operating Limits 
AC Port 
Power 
Power Factor 
Backfeed 
Factor 
(adjustable) 
Current 
Setting 
lead. / lag. 
(mA) 
18 
1.0 
0.8 / 0.8  
 
 
18
1.0
0.8 / 0.8  
 
 
18
1.0
0.8 / 0.8  
 
 
0.8 / 0.8  
18
1.0
18 
1.0 
0.8 / 0.8 
18 
1.0 
0.8 / 0.8  
18 
1.0 
0.8 / 0.8  
18 
1.0 
0.8 / 0.8 
18 
1.0 
0.8 / 0.8 
537620 Rev.D 
Efficiency 
Nom. Peak power 
(W) per unit area: 
m
/ ft
2
 
225/20.9 
221/20.5 
220/20.4 
212/19.7 
209/19.4 
196/17.3 
194/17.1 
191/16.9 
189/16.7 
Max. Units per Branch 
 (Europe – Australia) 
10 ‐ 11 
10 ‐ 11 
10 ‐11 
10 ‐ 11 
10 ‐ 11 
10 ‐11 
10 ‐ 11 
10 ‐ 11 
10 ‐ 11 
 
 
   7

Publicidad

Tabla de contenido
loading