LP GAS GRILL CONNECTIONS TO A GRILL OR COOKTOP (cont.)
Single Gas Cooktop or Grill Connection
3/8" Flare
Fitting
20-lb. Type 1 LP Tank
Built-in models shown.
For models installed on carts, open the tank storage drawer on the
right side to make the tank connection.

NATURAL GAS GRILL CONNECTIONS

• The gas supply line must be sized to
accommodate the outdoor grill and, if present, an
outdoor cooktop connected to the same gas
supply.
• The grill or cooktop and its individual shut-off
valve must be disconnected from the gas supply
during any pressure testing of the system at test
pressures in excess of 1/2 PSIG.
Regulator
3/4" Min. Dia.
Flexible Connector
Built-in models shown.
Make connection for models installed on carts in the same
manner. The entry for the gas line is on the back of the cart.
Outdoor Cooktop: Install the cooktop using the same method
illustrated above for the outdoor grills.

Installation Instructions

LP Hose and
Regulator
1/2" Male to 3/4"
Female Elbow
Incoming Natural
Gas Supply Pipe
3/4" NPT to
3/4" Flare
Fitting
Manual Shut-Off
Valve
Outdoor Cooktop: Install the cooktop with a
separate tank using the same method. Order
WB21X10156 Regulator hose assembly for the
20-lb. tank connection.
To connect 20-lb. LP tank:
• Attach the regular hose assembly to the brass
elbow. Do not use threading compound.
• Insert the coupler sleeve on the regulator over
the tank inlet; turn clockwise to tighten. Do not
overtighten the coupler.
To disconnect from the 20-lb. LP tank:
• Turn tank valve to OFF.
• Grasp the coupler sleeve, turn counterclockwise
and remove.
The installation of the outdoor grills or cooktop must
conform with local codes or, in the absence of local
codes, with the National Fuel Gas Code, ANSI
Z223.1, latest edition.
Operating pressure is 4" water column. Supply
pressure should be 5" to 14" water column. If
pressure is more than 14" water column, a
step-down regulator is required.
Check with the local gas utility or with local codes
for instructions on installing gas supply lines. Be
sure to check on type and size of run and how deep
to bury the line. If the gas line is too small, the grill
will not function properly.
• Install a manual gas shut-off valve in an easily
accessible location.
• Use threading compound on male threads only.
Do not use threading compound on the male end
of a flare adapter.
• Make connections as shown.
• Check to be sure the regulator arrow points in the
direction of gas flow, towards the grill and away
from the gas supply.
17