Pump Description - Lowara NSC Manual De Instalación, Funcionamiento Y Mantenimiento

Tabla de contenido

Publicidad

en - Original instructions
The nameplate provides information regarding the
impeller and casing material, the mechanical seal
and their materials. For more information, see
3
on page 375.
IMQ or TUV or IRAM or other marks (for electric
pump only)
Unless otherwise specified, for products with a mark
of electrical-related safety approval, the approval re-
fers exclusively to the electrical pump.

3.4 Pump description

• Connection dimensions according EN 733 (mod-
els 32-125...-200; 40-125...-250; 50-125...-250;
65-125...-315;80-160...-315; 100-200...-400;
125-250...-400; 150-315...-400).
• Volute casing pump with back pull out bearing
bracket.
3.5 Material
The metallic parts of the pump that come in contact
with liquid are made of the following:
Material code
Material cas-
ing / impeller
CC
Cast iron/Cast
iron
CB
Cast iron/
Bronze
CS
Cast iron/
Stainless steel
CN
Cast iron/
Stainless steel
DC
Ductil iron /
Cast iron
DB
Ductil iron /
Bronze
DN
Ductil iron /
Stainless steel
NN
Stainless steel /
Stainless steel
RR
Duplex/Duplex
3.6 Mechanical seal
Unbalanced single mechanical seal acc. EN 12756,
version K.
3.7 Application limits
Maximum working pressure
Figure 4
on page 379 shows the maximum working
pressure depending on the pump model and the
temperature of the pumped liquid.
P
+ P
≤ PN
1max
max
P
Maximum inlet pressure
1max
P
Maximum pressure generated by the pump
max
PN
Maximum operating pressure
Liquid temperature intervals
18
Figure 4
ture ranges.
Figure
For special requirements, contact the sales and
service representative.
Maximum number of starts per hour
kW
Starts
per
hour
Noise level
For the sound pressure levels of pump equipped
with standard supplied motor, see
380.
For sound pressure levels of pump without motor,
see
Table 10
4 Installation
Standard/
Optional
Precautions
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Optional
Grounding (earthing)
on page 379 shows the working tempera-
0.25
4.00
11
18.5
-
-
-
3.00
7.50
15
22
60
40
30
24
on page 384.
WARNING:
• Observe accident prevention regula-
tions in force.
• Use suitable equipment and protec-
tion.
• Always refer to the local and/or na-
tional regulations, legislation, and co-
des in force regarding the selection of
the installation site, plumbing, and
power connections.
Electrical Hazard:
• Make sure that all connections are
performed by qualified installation
technicians and in compliance with
the regulations in force.
• Before starting work on the unit,
make sure that the unit and the con-
trol panel are isolated from the power
supply and cannot be energized. This
applies to the control circuit as well.
Electrical Hazard:
• Always connect the external protec-
tion conductor to ground (earth) ter-
minal before making other electrical
connections.
• You must ground (earth) all electrical
equipment. This applies to the pump
equipment, the driver, and any moni-
toring equipment. Test the ground
(earth) lead to verify that it is connect-
ed correctly.
• If the motor cable is jerked loose by
mistake, the ground (earth) conductor
should be the last conductor to come
loose from its terminal. Make sure
that the ground (earth) conductor is
longer than the phase conductors.
30
45
90
-
-
-
37
75
160
16
8
4
Table 9
on page