Table 4
Choosing cable-entry devices for
Equipment in Potentially Explosive Atmospheres
Ex
Atmospheres
Gas
Gas
Dust
Support:
1
800-344-4634 • 1 708-534-4756
Support: 1 800-755-7621 • 1 708-587-3587
Model G-SPK Global Series Loudspeaker
Cable Entry Devices
(cable glands, stopping plugs, etc.
Cable entry devices shall be equipment certified
as flameproof. To maintain the ingress protection
of the flameproof loudspeaker enclosure, we
recommend the cable entry device be IP66
certified.
For the flameproof loudspeaker enclosure, cable
entry devices shall be equipment certified as
flameproof. To maintain the ingress protection
of the flameproof loudspeaker enclosure we
recommend the cable entry device be IP66
certified. For the increased safety terminal
enclosures (terminal boxes), cable entry devices
shall be equipment certified as increased safety
and shall maintain an IP rating of IP54.
Cable entry devices for the and terminal enclosures
shall be equipment certified as dust protected. To
maintain the ingress protection of the loudspeaker
and terminal enclosures the cable entry devices
shall be IP6X certified.