Blue Angel Pumps BSP25 Manual De Instrucciones De Operación Y Piezas página 5

Bomba de respaldo para sumideros
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance
Always disconnect the
electrical supply before
attempting to install, service,
relocate or per-form any maintenance.
If the power source is out of sight, lock
and tag in the open (off) position to
prevent unexpected power application.
Failure to do so could result in fatal
electrical shock. Only qualified
electricians should repair this unit.
Improper repair could result in fatal
electrical shock.
Once a month, check battery condition.
To check battery condition follow steps
listed below:
1. Unplug the wall charger.
2. For batteries with top caps that can
be removed, the electrolyte level
should be checked and filled to
manufacturer's specifications. The
charge for each cell should be
checked with a hydrometer. A
specific gravity of 1.265 indicates
the battery is at full charge. If the
specific gravity of any of the cells
varies more than .050, the battery
should be replaced.
NOTE: An inexpensive hydrometer
can be purchased at an automotive
parts dealer.
3. Inspect the terminals and clamps for
corrosion and tightness. Clean and
tighten as required.
4. Unplug the main pump and fill
sump with water until back up
pump turns on. Repeat process two
times to be sure pump is operating
normally.
5. If pump operates normally, plug
charger into wall outlet, turn on
main pump. If pump fails to
operate normally, see
Troubleshooting guide and correct
problem. Repeat step 5.
BATTERIES
Dangerous hydrogen gas can be
released from batteries while charging.
Sparks can ignite the gas in an enclosed
space. Wear safety goggles when
connecting batteries. Battery
connections should be made in a well-
ventilated area.
in the vicinity of lead acid batteries can
be dangerous. Before making
connections or servicing the batteries,
read and follow instructions in all
applicable instruction manuals. To
reduce the risk of battery explosion,
follow the instructions in this manual
and those published by the battery
manufacturer, as well as those of any
other equipment used in the
surrounding area.
5
If battery acid contacts your eye(s),
flush with cold running water for 10
minutes and seek immediate medical
attention. If acid contacts your skin or
clothing, wash immediately with soap
and water.
allow a spark or flame in the vicinity of
the battery.
dropping metal tools on the battery
posts because they may spark or short-
circuit the system or battery, causing an
explosion.
Follow battery manufacturer's
maintenance procedures and schedules.
Be certain that the area around the
batteries is well ventilated. Before
servicing the batteries, blow away
gasses by waving a piece of cardboard
Working
near the batteries.
www.blueangelpumps.com
BSP25
Never
smoke or
Avoid

Publicidad

Tabla de contenido
loading

Tabla de contenido