Air-to-water Heat Pump Split Versati
2V1_ON
2V1_OFF
3V2_ON
3V2_OFF
2V2_ON
2V2_OFF
3V1_ON
3V1_OFF
INDOOR_PUMP
CN8
SOLAR_PUMP
POOL_PUMP
Copyright 2018. This translation is property of GREE PRODUCTS SL. All rights reserved. Total or partial reproduction without its express authorization is prohibited.
X7
Electric magnetic 2-way valve 1 is normally open
X8
Electric magnetic 2-way valve 1 is normally closed
X12
Electric magnetic 3-way valve 2 is normally open
X11
Electric magnetic 3-way valve 2 is normally closed
X13
Electric magnetic 2-way valve 2 is normally open
X14
Electric magnetic 2-way valve 2 is normally closed
X21
Electric magnetic 3-way valve 1 is normally open
X22
Electric magnetic 3-way valve 1 is normally closed
CN4
Control of the water pump for the main unit
CN8
Reserved
CN7
Control of the water pump for solar system
CN9
Control of the water pump for the main unit