Emotron VSA 23 Manual Del Usuario página 49

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Parameter function list
Basic menu function list
Table 23
Menu Function Description
Preferred view
Status display parame-
110
ters
Main setup, Operation
211
Control mode
Frequency command
212
source
213
Run command source
214
Reset mode
Local/Remote fre-
quency control select
215
(Run command by the
Run/Stop key)
216
Reverse run instruction
217
Fan control
48
Programming instructions and menu list
Range/ Code
000: No display
001: Display
000: Vector control
001: V/F Control
000: Up/Down key on control panel
001: Potentiometer on control panel
002: AIN input signal from (TM2)
003: Multi-function input terminal Up/
Down function
004: RS-485 Communication frequency
setting
000: Keypad
001: External Terminal
002: Communication control
000: RUN instruction is OFF, Reset com-
mand is available.
001: Whether RUN instruction is OFF or
ON, Reset command is available.
000: Up/Down key on keypad sets fre-
quency
001: Potentiometer on the keypad set fre-
quency
000: Reverse enable
001: Reverse disable
000: Auto-run at set temperature
001: Run when VSD runs
002: Always run
003: Always stop
Factory
Default
000
000
000
000
000
000
000
001
Emotron AB 01-3991-11r2
Remarks
*1
*4

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vsa 48