Table 23
Menu Function Description
364
Preset frequency 3
365
Preset frequency 4
366
Preset frequency 5
367
Preset frequency 6
368
Preset frequency 7
369
Preset frequency 8
Process and application parameters, PID Process control
381
PID operation mode
382
PID Offset
383
P: Proportional gain
384
I: Integral time (s)
385
D: Differential time (s) 0.00 to 10.0
Load monitor
411
Alarm Select
412
Alarm Trip
413
Ramp Alarm
414
Alarm Start Delay
415
Load Type
416
Max Alarm Margin
417
Max Alarm Delay
418
Max Pre-Alarm Margin 0 to 400%
Emotron AB 01-3991-11r2
Range/ Code
00.0 to 200 Hz
00.0 to 200 Hz
00.0 to 200 Hz
00.0 to 200 Hz
00.0 to 200 Hz
00.0 to 200 Hz
000: PID Function unavailable
001: PID Control, Bias D control
002: PID Control, Feedback D control
003: PID Control, Bias D reverse charac-
teristics control.
004: PID Control, feedback D reverse
characteristics control.
000: Positive direction
001: Negative direction
0.00 to 10.0
00.0 to 100
000: Off
001: Min
002: Max
003: Min+Max
000: Off
001: Min
002: Max
003: Min+Max
000: Off
001: On
0 to 999 s
000: Basic
001: Load Curve
0 to 400%
0 to 90 s
Programming instructions and menu list
Factory
Remarks
Default
10.0
*1
20.0
*1
30.0
*1
40.0
*1
50.0
*1
60.0
*1
000
000
*1
01.0
*1
10.0
*1
0.00
*1
000
*1
000
*1
000
*1
002
*1
000
*1
015
*1
01.0
*1
010
*1
53