9.5.2
STOVE OR INSERT IN OPERATION
The hot air fan will start when the smoke temperature reaches a minimum. In this moment, the stove is correctly burning. After
EN
this, our stove will be working normally.
The control shows the ambient temperature in the room.
21º C
SET TEMPER
ROOM
MENU
9.5.4
ROOM TEMPERATURE REACHES TEMPERATURE FIXED BY THE USER
When the ambient temperature (of the room) reaches the value set by the user or the smoke temperature reaches a too high
value, the stove will automatically operate at one lower power, it means that modulates in power.
Remember that if it is activated "stand-by mode", when the ambient temperature reaches the value set by the user plus a
differential (2ºC) the stove will be automatically turned off and will be on hold until the ambient temperature falls to the set
temperature minus a differential (2ºC). After that, the stove restarts automatically.
16:40
22º C
P-2
BURNER
CLEANING
MENU
21:28
23º C
P-3
OFF
MENU
9.5.8
RE-IGNITION OF THE STOVE
When the stove is turned off it would not be possible to restart it up until some safety time goes by and the stove is cold
enough. If you try to start-up the stove, the display will show up the following information:
44
9.5.3
CHANGE OF THE SET-POINT ROOM TEMPERATURE
In order to modify the setting room temperature, please press button 4 and then buttons 1 and 2 to increase or decrease it
respectively.
9.5.5
BURNER CLEANING
While the stove is working normally, some automatic cleanings of the burner take place in several minutes intervals. This
process consists of cleaning the rest of pellet remaining in the burner in order to guarantee a proper working of the stove and
it takes several seconds.
9.5.6
TURNING OFF THE STOVE OR INSERT
In order to turn off the stove, press button no.3 during a few seconds. Once it has been turned
off, it will start the final cleaning stage, in which the pellet supply stops and the smoke extractor
will be working to the maximum speed. This stage would not finish until the stove has reached
the appropriate cooling temperature.
9.5.7
STOVE TURNED OFF
When the stove is turned off, the control shows the following information (see drawing D92):
15:18
21º C
P-3
WORKING
MENU
16:40
27º C
P-2
WORKING
MODULATE
MENU
21:10
23º C
P-3
FINAL
CLEANING
MENU
STAND-BY
COOL
MENU