12 mm
8
10 mm
17 mm
3
1
2
4
20 mm
4.
Remove the lid, center section and lower section of the storage
compartment.
5. Remove the edge protection on the lower storage compartment and
provide a recess for the alarm system cable as illustrated.
6. Loosen the cable ties on the alarm system wiring harness and install
the cables in the lower storage compartment. Run the alarm system
cables through the recess, attach the edge protection and mount the
lower storage compartment.
7. Remove the dummy plug (1).
8. Clean and degrease the back of the alarm system and the lower storage
compartment. Center the self-adhesive Velcro tape (2) on the back of
the alarm system. Press the second Velcro tape against it. Remove the
protective film on the Velcro tape, position the alarm system so it rests
against the left and front wall of the lower storage compartment and
press together firmly. If the Velcro tape is correctly mounted, it should
be strong enough to hold the alarm system in place. You can also hold
the alarm system in place with cable ties. First drill four holes in the
lower storage compartment and insert the cable ties through the holes.
Connect the alarm system to the wiring harness. Place rubber grommet
(3) over the alarm system and secure it in position (4) using the cable
binder.
9. Connect the center storage compartment and lid with the quick release
while still dismounted. Clean and degrease on the inside. Mount the
self-adhesive REED switch (with cable) in the center storage
compartment and the self-adhesive REED switch (without the cable) in
the storage compartment lid (measured approx. 20 mm from the rear
edge - see photo) no more than 4-5 mm apart. Mount the center
storage compartment and connect the REED switch connector to the
alarm system wiring harness.
10.Read the operating manual of the alarm system 601.12.035.000
carefully and then check the function of the alarm system. Also check
the function of the REED switch. To do so, activate the alarm system,
unlock the quick release of the storage compartment and raise the
storage compartment cover.
Keep the hand-held transmitter ready to be able to switch the alarm off
at any time since the alarm siren sound reaches a volume of 114 dBA.