EN
User Manual
DC/AC Power Inverter
6
Fan
To save energy, the fan only works when
○ the load is > 30% of the rated power of the power inverter
○ and/or the internal temperature of the inverter is > 60 °C.
7
LED status indicator
Status description
Function
LED
Alarm
green
Input low
on
yes
voltage alarm
red off
Input low
green
voltage shut-
on
yes
down
red on
green
Input overvolta-
on
no
ge shutdown
red on
green
Overload
on
no
shutdown
red on
green
Over tempera-
on
yes
ture shutdown
red on
green
Output short
on
no
circuit
red on
8
Changing the Fuse
Risk of overloading and fire
•
Only use fuses of the original strength!
•
Never use stronger fuses. See also chapter 2.4 "Specifications".
1. Disconnect the 12 V vehicle plug.
2. Pull the fuse from the rear of the housing.
3. Insert a new and identical fuse.
9
Maintenance, Care, Storage and Transportation
The product is maintenance-free.
Material damage
•
Only use a dry and soft cloth for cleaning.
•
Do not use detergents or chemicals.
•
Store the product out the reach of children and in a dry and dust-protec-
ted ambience when not in use.
•
Store cool and dry.
•
Keep and use the original packaging for transport.
•
Keep ventilation openings and cooling fins clean.
10 Liability Notice
•
We reserve the right to printing errors and changes to product, packa-
ging or product documentation.
•
See our terms of warranty. These are available in their current form un-
der the given contact details.
11 Disposal instructions
11.1 Product
According to the European WEEE directive, electrical and electronic
equipment must not be disposed with consumers waste. Its compo-
nents must be recycled or disposed apart from each other. Otherwise
contaminative and hazardous substances can damage the health and
pollute the environment.
As a consumer, you are committed by law to dispose electrical and electronic
devices to the producer, the dealer, or public collecting points at the end of the
devices lifetime for free. Particulars are regulated in national right. The symbol
REV2020-11-23
V2.1aw
Subject to change without notice.
Method for restart
AC
output
When the battery returns to
yes
normal voltage, the alarm au-
tomatically stops.
When the battery is back to
normal voltage, the power in-
verter continues to work auto-
no
matically.
- green on
- red off
When the battery has retur-
ned to its normal voltage, the
power inverter continues to
no
work automatically.
- green on
- red off
Reduce the load to the speci-
fied continuous load.
The power inverter then con-
no
tinues to work automatically.
- green on
- red off
Let the power inverter cool
down.
When the power inverter has
returned to the specified ope-
no
rating temperature, it continu-
es to work automatically.
- green on
- red off
Eliminate the cause of the
short circuit.
no
The power inverter then con-
tinues to work automatically.
on the product, in the user manual, or at the packaging alludes to these terms.
With this kind of waste separation, application, and waste disposal of used
devices you achieve an important share to environmental protection.
WEEE No: 82898622
11.2 Packaging
Packaging can be disposed of free of charge at the suitable collection
points – paper belongs in paper bins, plastics belong in yellow sacks
and glass belongs in used glass bins.
DE4535302615620
12 EU Declaration of conformity
With the CE sign Goobay®, a registered trademark of the Wentronic
GmbH ensures, that the product is conformed to the basic European
standards and directives.
13 ECE sign
With the ECE sign Goobay®, a registered trademark of the Wentronic
GmbH, ensures, that the required tests and approvals have been
carried out and an ECE aproval has been granted.
10R-06 15531
14 Symbols used
For indoor use only
Alternating current
Direct current
Recycling
- 4 -
IEC 60417- 5957
IEC 60417- 5032
IEC 60417- 5031
ISO 7001 - PI PF
066
by Wentronic GmbH | Pillmanstraße 12
38112 Braunschweig | Germany
52767
Goobay®