Technical Specification
2-Wire CANBus
4-Wire CANBus system
Power
Consumption
Connections
Operating temperature
Dimensions
Installation
Basic (default) installation:
[12V Pictogram, 4-Wire CANbus, External Mic, External Speaker, Internal Battery OFF,
single elevator shaft]
(1) CAN
Step 1
Connect 4-Wire CANbus to the
CAN port. The other end of the
CANbus should be connected
to the DCP to provide Power to
the unit.
(3/4)
Ext. Mic &
Speaker
Step 4
(2) Alarm
Place the external mic. And
external speaker in a location
that the device can function
properly.
Step 5
Programme the TOC DAU to the
desired usage (pg. 9)
8-28VDC 250mA max from external power supply.
CAN H and CAN L communication connected to
the DCP. Device requires external battery backup
to be set (see installation instructions 6, below).
Device receives power from DCP or CANBus
splitter (with power supply). No external power
supply required.
Supply voltage 8 – 12VDC
43mA – 190mA
CANbus and LPBus (RJ45)
-10ºC to +65ºC
77x180x60mm
Step 2
Wire the alarm button to the
alarm inputs on the TOC DAU.
Step 3
Connect the Ext. LED's wiring
to the pictograms located on
the COP.
Step 6
Test the functionality is correct
before leaving site.
2