The table below indicates all the parameters which can be set on the DAU (please
check DCP install guide for further details):
CMD
Description
Direct the first alarm call to DCP telephone (0-No,
PC07
1-Yes)
PC08
Alarm call bypass filter time (0-10s)
PC09
Reset to Factory Default
PC10
Reboot Digital Audio Unit
PC11
Alarm Button countdown timer (s)
PC12
Alarm filter input (0-Off, 1-On)
PC13
Cancel alarm by pressing alarm button (0-Off, 1-On)
PC14
Wait for Alarm acknowledgement (0-Off, 1-On) *
PC15
Automatic End of Alarm EOA (0-Off, 1-On)
PC16
Privacy Mode ** (0-off, 1-On)
PC19
Car alarm input NO (0) or NC (1)
PC21
LED Mode (0-Full, 1-EN81-28)
PC22
Alarm call retry attempts
PC23
Maintenance call retry attempts
PC24
Elevator Car microphone volume
PC25
Elevator car speaker volume
PC26
Elevator car announcement volume
Language ***
PC28
(1 – Spanish, 2 – Portuguese, 3 – Italian, 4 – English,
5 – German, 6 – French)
PC29
Time between alarm calls (s)
C = number of the car you need to check / configure
*If the Alarm Acknowledgement is on, the operator must press "0" to acknowledge the alarm
**The microphone inside the car is disconnected if there's no emergency alarm call
***The DAU can use up to six languages, each digit being its sequence order
Default Value
0
10
N/A
N/A
3
0
0
1
0
1
0
1
5
3
5
5
5
100000
0
9