Installing The Battery - HAMPTON BAY Victoria El Manual Del Propietario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Restore power to ceiling fan
and test for proper operation.
This fan is preprogrammed at the factory to
operate normally after batterry is installed in
hand-held remote and the power is turned on
to the fan. No additional programming should
be requried. If the fan either does not operate
properly or does not function, please go
through the programming CODE procedure:
With fan power off. Turn fan power on, press
and hold "FAN OFF" button on front of
remote for 10 seconds .when the fan light
blinks twice and the fan rotates for 3 second,
that means the programming code procedure
is finished.
1. "1,2,3,4,5,6" buttons:
To control the ceiling fan speed 1-6
2. "FANOFF" button:
This button turns the fan off.
3. The "LIGHT" button turns the light ON
or OFF . Press and hold the button for the
desired brightness.
The light will cycle continuously between
bright and dim setting as long as the
button is held down.
The light key has auto resume. It will stay
at the same brightness as last time when it
was turned off.
4. Reverse function button: To control fan
direction.
Special Note
The Victoria DC motor will move back and forth
when the fan is turned on or the speeds are changed.
This is quite normal as the internal magnets are
detecting the precise RPM at which to run the fan
motor. Once the correct calibration is finished the
fan will run smoothly.

Installing the battery:

Install 12 volt battery (included), to prevent damage
to transmitter, remove the battery if not used for
long periods.
WARNING
DO NOT SHORT-CIRCUIT, DISASSEMBLE,
HEAT UP, CONNECT IMPROPERLY OR
DISPOSE OF IN FIRE DO NOT RECHARGE,
MIX WITH USED OR OTHER BATTERY
TYPES. IMMEDIATELY REMOVE USED UP
BATTERIES.
Note:
The receiver (inside the motor) provides the
function of multiplicative protection.
1. Lock position: The DC motor has a built-in safety
feature against obstruction during operation. If this
occurs, the motor will discontinue operation within
3 seconds of interruption. To reset, simply disable
power supply to the fan motor and re-start.
2. Over 80W protection: When the receiver detects
power consumption is greater than 80W, the
receiver power will be stopped and operation will
immediately discontinue. To reset, simply disable
power supply to the fan motor and re-start.
3. Blade setup of motor is arranged according to
loading condition; please only install approved
blades from a certified dealer or this may void the
factory warranty.
2
1
3
FAN
LIGHT
OFF
6
4
5
Figure 20
Reverse function
button
Figure 21
8

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido