Descargar Imprimir esta página

Malfunctions; Technical Data - diversey TASKI vacumat 12 Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 78

Malfunctions

Malfunction
Machine without function
Foam or liquid leaking from the ma-
chine
Floor remains wetSoiled water is not
vacuumed up
Poor suction performance

Technical data

Machine
Rated voltage
Frequency
Rated power, nominal
Dimensions (LxWxH)
Main cord length
Maximum weight of opera-
tional machine
Tub capacity wet/dry +/-
5%
Possible causes
Machine is switched off
No power supply
Main cord defect
Defective ON/OFF switch
Motor does not turn
Float malfunction
Tank full
Fixomat squeegee not correctly ad-
justed
Tank full
Filter cloth soiled
Filter disc dirty
Hose or dust nozzle blocked
Coarse filter soiled
Fixomat squeegee not correctly ad-
justed
vacumat 12
220-240V~
110-120V~
50-60
60
1000
850
39x44x55
39x44x55
10
10
10
10
12 / 18
12 / 18
Troubleshooting
• Switch on the ON/OFF switch
• Insert the plug into the mains sock-
et
• Replace the main cord
• Contact your service partner
• Contact your service partner
• Switch off ON/OFF switch.
• Check the float to make sure it is
fully functional and repair any fault
• Repair any fault
• Empty the tank
• Re-adjust Fixomat squeegee
• Replace the blade
• Empty the tank
• Clean or replace the filter cloth
• Replace the filter disc
• Remove the blockage
• Clean or replace coarse filter
• Re-adjust Fixomat squeegee
• Replace the blade
vacumat 22
220-240V~
110-120V~
50-60
60
1000
850
39x44x65
39x44x65
10
10
10.5
10.5
22 / 28
22 / 28
vacumat 22T
220-240V~
110-120V~
50-60
60
1000
850
90x70x98
90x70x98
10
10
19
19
22 / 28
22 / 28
Page
68
68
EN
68
68
68
68
68
68
68
AC
Hz
W
Cm
m
Kg
L
73

Publicidad

loading

Este manual también es adecuado para:

Taski vacumat 22Taski vacumat 22t