Descargar Imprimir esta página

Malfunctions; Technical Data - diversey TASKI dorsalino Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54

Malfunctions

Malfunction
Machine without function
Machine switches off during opera-
tion
Poor suction performance

Technical data

Machine
Rated voltage
Frequency
Rated power, nominal
Dimensions (LxWxH)
Main cord length
Maximum weight of operational machine
Values according to IEC 60335-2-69
Sound pressure level LpA
Uncertainty KpA
Vibration
Uncertainty K
Protection class
Possible causes
Machine is switched off
No power supply
Main cord defect
Defective ON/OFF switch
Motor does not turn
Self-resetting temperature sensor
triggered
Hose or dust nozzle blocked (e.g.
bits of wood, bits of fabric)
Double filter paper bag full
Hose not correctly installed
Filter cloth soiled
Coarse filter soiled
Troubleshooting
• Switch on the ON/OFF switch
• Insert the power supply plug into
the mains socket
• Replace the main cord
• Contact your service partner
• Contact your service partner
• Check the double filter paper bag
dorsalino for overfilling
• Check the admission accessories
The machine switches on automatically after
cooling of the vacuum motor (approx. 10 to
20 min.)
• Remove any foreign matter
• Replace the double filter paper
bag
• Check the hose
• Clean or replace the filter cloth
• Clean or replace coarse filter
dorsalino
220-240V~
100-120V~
50-60
50-60
800
850
52x32x30
52x32x30
15
15
5.4
5.4
<70
2.5
<2.5
0.25
II
Page
46
46
EN
47
47
47
48
AC
Hz
W
cm
m
kg
dB(A)
dB(A)
m/s2
m/s2