Descargar Imprimir esta página

Hansgrohe 15840180 Instrucciones De Montaje página 6

Ocultar thumbs Ver también para 15840180:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 10
Warning - hazardous electrical
voltage
CAUTION!
Must be adhered to!
NOTE
Indicates information, whose content
is important and must be observed.
Electrical fi tter
Installation tool/installation
sequence
Dimensions (Page 24)
Installation dimensions (page
25)
Specifications (Page 7)
Installation plans
(Page 26-29)
Note: Read the operating instructions before you
begin the installation. They contain information
regarding the safe and proper installation.
Installation
All work on the RainBrain may only be carried out
in a de-energized state!
All components must remain accessible.
Wear safety clothes during the installation.
Risk of fire - installation box
There must not be any fl ammable materials present
in the immediate vicinity.
The ambient temperature must not exceed 50
°C.
6
Specifi cations
The terminal block must be installed in protection
area 2.
When calculating the accumulator size and the
drain, you must consider that up to 42.5 litres/min
may be required for 0.3 MPa mixing water - depen-
ding on which showers will be combined.
Technical Dates
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temperature:
Fitting dimensions:
Fittings:
Free discharge at 0.3 MPa:
Note: The terminal block must be installed
horizontally (Hansgrohe scribe must be legible).
Supply lines from below.
Electrical fitter
All installation and inspection procedures must
be carried out by an approved electrician and
in accordance with VDE 0100 Part 701 and IEC
60364-7-701.
Electrical connection
Mains supply 230V/N/PE/50Hz (3x1.5mm²
length 0.5m). For electrical installation, all appli-
cable VDE, country-specifi c and EVU regulations in
their respectively valid versions must be observed.
Potential equalisation is required at the site (4mm²,
cable length 1m).
Leakage current protection device
The fusing must be conducted via a leakage cur-
rent protection device (RCD/FI) with a measuring
diff erential power of 30 mA.
Prelock
Consumers 1 - 5
Installation of fi ttings jumper see page 30:
Installation of basic set see page 32:
English
max. 1 MPa
0.1 - 0.5
1.6 MPa
max. 80° C
65° C
G ¾
cold on the right
warm on the left
42.5 l/min
Installtion zones electrical systems
in accordance with VDE0100 part
701
Arrangement and cable installation
see page 28
Fasteners
Only use the proper fasteners! The included screws
and dowels are only suitable for concrete.
Cleaning see page 31, illustration 5
Rinse the entire installation as per DIN1988 /
EN1717.
Drain capacity
The drain capacity must be at least 50 l/min.
Installation of basic set display page 32:
Figure 8:
Plaster in the basic set display, or install wall cove-
ring if installed in front of wall.
Figure 9:
After the plastered wall surface has dried, spray
the seam between the wall and the plastic casingn
with silicone (free of acetic acid!).
Figure 10:
Coat the wall with PCI-Lastogum or a compa-
rable sealing compound as instructed by the
manufacturer.
Figure 11:
Place the sealing collar over the plastic casing and
press it into the glue and the silicone.
The sealing sleeve (F page 24) must
not be heat-sealed
Repair
Only by Hansgrohe qualifi ed personnel or persons
or companies designated by Hansgrohe.

Publicidad

loading