appropriate value.
6. Ensure that both "Center Spot" and "Temp.
Max" are both set to ON for temperature
screening mode
7. If the thermal imager measures a
temperature that is higher than the Alarm
Temperature, the Center Point Temperature
reading it will be displayed in RED. See
image below.
CAPTURE/SAVE IMAGES USING
THE INTERNAL MEMORY
The imager can save 20 images on internal memory. The saved images
can be transferred to an iOS or Android device or to a PC via Bluetooth
1. Point the unit at an object or an area of interest.
2. Short press the trigger to capture the image.
3. To discard the image, short press the trigger again. The display
will return to a live image.
4. Press "SAVE" to save the image to memory
5. If the image is stored successfully on the internal memory, the display
will return to live mode.
6. To erase/format internal memory please refer to Section 6, Settings
Menu.
SHARE IMAGES USING BLUETOOTH
INSTANT SHARE
The 52070F thermal imager has Bluetooth
images to be transferred to an iOS or Android device with the Thermview+
app installed.
1. Press the OK button to enter the
2. Access the Setup Menu buy pressing
3. Press the OK button to enter Setup menu.
4. Turn Bluetooth
®
capability to allow thermal
®
Settings Menu
the Down Arrow button
There are three available options:
Bluetooth
, Brightness, and Auto Off
®
ON
®
.
®