INTRODUCTION
The Yellow Jacket
52070F Thermal Imager is an accurate, high-qual-
TM
ity handheld thermal imaging camera. The 52070F has a special mode
specifically for elevated skin temperature screening called Temperature
Screening Mode. When the 52070F thermal imager is operated in the Tem-
perature Screening Mode, the thermal imager meets the recommendations
established by the U.S Food & Drug Administration (FDA) for elevated skin
temperature screening. When operated in Temperature Screening Mode, the
52070F has a measurement accuracy of ±0.9F (±0.5C) over a temperature
screening range of 93.2-102.2°F (34-39°C). The thermal imaging camera
has been calibrated in the factory using a blackbody temperature reference
source. No on-site calibration is required.
Meets international performance standards for thermographic devices.
Not FDA-cleared or approved.

KEY FEATURES

• Temperature Screening Mode
• 80x80 thermal resolution or 6400 temperature measurement points
• 50Hz frame rate. The camera creates images at the rate of 50 per
second so moving subjects appear clearer
• Hot, Cold, Center temperature tracking
• Large, easy-to-read graphical TFT display
• Bluetooth
image sharing to Thermview+ iOS and Android app
®
• Scene temperature range Lock
• Buzzer alarm.
• 8 hours operating time with rechargeable battery.
• Compact, rugged design
THE THERMVIEW+ MOBILE APPLICATION ("PROGRAM") IS OFFERED
BY SHENZHEN EVERBEST MACHINERY INDUSTRY CO., LTD. NEITHER
SOUTHWIRE COMPANY, LLC OR ANY OF ITS AFFILIATES SHALL BE
RESPONSIBLE FOR OPERATION OR FUNCTIONALITY OF THE PROGRAM.
YOU ASSUME THE ENTIRE RISK AS TO THE RESULTS AND PERFORMANCE OF
THIS PROGRAM. ADDITIONALLY, SOUTHWIRE COMPANY DOES NOT WARRANT,
GUARANTEE, OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF, OR
THE RESULT OF THE USE OF, THE PROGRAM IN TERMS OF CORRECTNESS,
ACCURACY, RELIABILITY, CURRENTNESS, OR OTHERWISE, AND YOU RELY ON
THE PROGRAM AND RESULTS SOLELY AT YOUR OWN RISK. YOUR USE OF
THE PROGRAM IS GOVERNED BY THE POLICIES, PROCEDURES AND PRIVACY
PRACTICES OF SHENZHEN EVERBEST MACHINERY INDUSTRY CO., LTD.
IMPORTANT INFORMATION CONCERNING ELEVATED
SKIN TEMPERATURE SCREENING
• Temperature measurement should not be solely or primarily relied upon
to diagnose or exclude a diagnosis of COVID-19, or any other disease
• Elevated body temperature in the context of use should be confirmed
with secondary evaluation methods (e.g., an FDA approved non-contact
infrared thermometer (NCIT) or a clinical grade contact thermometer)
• Public health officials, through their experience with the device in the
particular environment of use, should determine the significance of any
fever or elevated temperature based on the skin telethermographic
temperature measurement
• The thermal imaging camera should be used to measure only one
subject's temperature at a time
• Visible thermal patterns are only intended for locating the points
from which to extract the thermal measurement.
RECOMMENDATIONS FOR USING THE THERMAL IMAGER
FOR ELEVATED SKIN TEMPERATURE SCREENING
(Consistent with ISO/TR 13154: 2017 guidelines on thermograph usage)
Preparing the Area where you will use the thermal imaging system
• Recommended room temperature should be 64-86 °F (18-30 °C)
with a relative humidity of 60 percent.
• Try to control other conditions that could impact the temperature
measurement:
• Avoid reflective backgrounds (for example, glass, mirrors, metallic
surfaces) to minimize reflected infrared radiation.
• Set up the thermal imaging camera in a room with minimal movement