Warnings
Operating Range
H.P. OP/ELEC OP
H.P. Prog/ELEC Prog
Setting the programming ranges is subject to the below rules:
- Programs start 15 minutes after being entered.
- The total time of both ranges has to be at least 8 hours;
- The first program's duration has to be set between 4 and 12 hours.
- The second program's duration can be set at zero if the first program is set
to be at least 8 hours.
- If the second program's duration is not set at zero, it has to be at least 2
hours.
Anti-Legionella
If the legionella function mode has been activated, the device will heat up to a nominal
temperature of 62° C while the function is active. This mode will reduce the device's ove-
rall performance and is only useful if there are repeatedly extensive absence periods or if
an expansion tank is being used.
Emergency mode
This mode is activated in case of malfunction or if the external aggregate fails. In this
mode, only the electric heating element will be heated up to a nominal temperature of
65 °C.
In this mode, only 50% of the hot water amount can be guaranteed for the 270 l model.
Electrical backup
The electrical boost will never start if the automatic operation of the electrical boost is
disabled.
Resetting
This menu allows you to return to the default settings.
Date and time
Define the date, then confirm. Proceed as above for month, year, hours, and minutes.
This menu is accessible through the Settings menu, in Browse mode (excluding Installer
mode).
Presentation
Installation conditions
(see diagram on the cover)
• Wiring as shown in figure
2
• Power supply contract
with off-peak hours option.
• Wiring as shown in figure
1
• Program one or two
operating ranges of at
least 8 hours in total. The
programmed hours are
adjustable.
Installation
Switching on heat pump and
electric heating element
If the off-peak hours-signal is
received on the electric control
panel, if hot water is needed.
At programmed times, if hot wa-
ter is needed.
Example: Heat pump and
electric heating element can be
activated between 22:00 and
6:00 and between 12:00 and
14:00
27