OPERATIONS
Operating Instructions
With the unit filled and plugged in, press the POWER button and the backlit control
panel will illuminate.
NOTE: The backlit control panel stays illuminated for 3 minutes after initial power-
up and anytime the controls are adjusted.
NOTE: For best cooling, we recommend turning on the pump 2 or 3 minutes before
turning on the fan. This allows the media to become saturated for faster cooling
effect.
NOTE: This unit can be used as a fan only or an evaporative cooler. If no
evaporative cooling is desired, simply do not engage the pump and use only the
fan feature.
For Evaporative Cooling:
With the unit already turned on:
1. Press the PUMP button. This will activate the pump to begin saturating the
media.
2. Press the SPEED button to engage the fan. The 3-speed fan starts in High and
can be adjusted down by pressing the SPEED button again.
3. During this function, the FAN portion of the display will show the icon
representing the selected speed, the PUMP portion of the display will be
illuminated and active, and the center portion of the display will show the COOL
(snowflake) icon indicating the evaporative cooling function in engaged.
ALL ICONS SHOWN FOR REFERENCE
4