Interconnection
" " used for interconnecting lights. As many as 10 lights of this type can be connected
in parallel. (Fig . 4 .1)
5 . Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• When installing the light, make sure the installation site is not subject to vibration.
• Select an appropriate mounting location, taking the reach and motion detection
into consideration.
The most reliable way to detect movement is given by mounting the light to point
across the direction in which people walk and by making sure no obstacles (e.g.
trees, walls etc.) interrupt the line of sensor vision.

Mounting procedure

• Switch OFF power supply. (Fig . 4 .1)
• Undo locking screw and detach light enclosure from wall mount. (Fig 5 .1)
• Detach plug-in terminal and remove light enclosure from wall mount. (Fig . 5 .2)
• Mark drill holes. (Fig . 5 .3)
• Drill holes and fit wall plugs. (Fig . 5 .4)
• Concealed mounting. (Fig . 5 .5)
• Surface-mounted installation with spacers. (Fig . 5 .6)
• Attach retaining strap to the wall mount and fit plug-in terminal. (Fig . 5 .7)
• Connect conductors. (Fig . 5 .8)
• When interconnecting several lights, break out safety tab. (Fig . 5 .8)
• Fit light enclosure onto wall mount. (Fig . 5 .9)
• Screw in locking screw. (Fig . 5 .9)
• Switch ON power supply. (Fig . 5 .9)
• Make settings ➜ "6 . Function"
6 . Function
Spot ONE Sensor/Spot DUO Sensor
Factory settings
– Twilight level: 1000 Lux
– Time setting: 8 seconds
Twilight setting (Fig . 6 .2 F)
The chosen response threshold can be infinitely varied from approx. 2 to 1000 Lux.
– Control dial set to
= daylight mode (not depending on ambient brightness)
– Control dial set to
= night-time operation (approx. 2 lux)
18
The control dial must be turned to
forming the functional test in daylight.
Time setting (Fig . 6 .2 G)
The light's stay ON time can be set to any period from approx. 8 seconds to a
maximum of 35 minutes. Any movement detected before this time elapses will restart
the timer.
– Control dial set to + = approx. 35 minutes
– Control dial set to – = approx. 8 seconds
Note:
After the light switches OFF, it takes approx. 1 second before it is able to start detect-
ing movement again. The light will only switch ON in response to movement once this
period has elapsed.
Spot DUO Sensor
Factory configuration:
Both light heads are interconnected and always switch ON and OFF at the same time.
To operate the two light heads separately, the connection between the terminals must
be removed ( 1 and 2).
Spot ONE Sensor Connect/Spot DUO Sensor Connect
Factory settings
– Twilight level: 2000 lux
– Time setting: 5 seconds
Smart Remote app
To configure the light via smartphone or tablet, you must download the STEINEL
Smart Remote app from your app store. You will need a Bluetooth-capable smart-
phone or tablet.
Android
when adjusting the detection zone and per-
iOS
19