Model Designation; Airborne Noise Emission; Limiting Concentration - LG ARNU483BRZ4 Manual De Instalación

Ocultar thumbs Ver también para ARNU483BRZ4:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model Designation

ARN
U
96
3

Airborne Noise Emission

The A-weighted sound pressure emitted by this product is below 70 dB.
** The noise level can vary depending on the site.
The figures quoted are emission level and are not necessarily safe working levels. Whilst there is a cor-
relation between the emission and exposure levels, this cannot be used reliably to determine whether
or not further precautions are required. Factor that influence the actual level of exposure of the work-
force include the characteristics of the work room and the other sources of noise, i.e. the number of
equipment and other adjacent processes and the length of time for which an operator exposed to the
noise. Also, the permissible exposure level can vary from country to country. This information, however,
will enable the user of the equipment to make a better evaluation of the hazard and risk.

Limiting concentration

Limiting concentration is the limit of Freon gas concentration where immediate measures can be
taken without hurting human body when refrigerant leaks in the air. The limiting concentration shall
be described in the unit of kg/m
■ Calculate refrigerant concentration
Refrigerant concentration =
B8
Z
4
Serial Number
Combinations of functions
A:Basic function
C: Plasma(Ceiling Cassette)
G: Low Static
U: Floor Standing without Case
SE/S8 - R: Mirror V: Silver B:Blue(ART COOL Type Panel Clolr)
SF
- E: Red
Q: Console
Chassis Name
Electrical Ratings
1:1Ø, 115V, 60Hz
6:1Ø, 220 - 240V, 50Hz
3:1Ø, 208/230V, 60Hz
Total Cooling Capacity in Btu/h
EX) 5,000 Btu/h ➝ '05'
Combination of Inverter Type and Cooling Only or Heat Pump
N: AC Inverter and H/P
U: DC Inverter and H/P and C/O
❈ LGETA:U Ex) URN
3
(Freon gas weight per unit air volume) for facilitating calculation
Limiting concentration: 0.0000158 lb/inch
Total amount of replenished refrigerant in refrigerant facility (lb)
Capacity of smallest room where indoor unit is installed (inch
L: Neo Plasma(Wall Mounted)
K: High Sensible Heat
V: Silver G:Gold
1: Kiss (Photo changeable)
Z: Outside Air Unit
2:1Ø, 220V, 60Hz
7:1Ø, 100V, 50/60Hz
G:1Ø, 220 - 240V, 50Hz/1Ø, 220V, 60Hz
18,000 Btu/h ➝ '18'
V: AC Inverter and C/O
System with Indoor Unit using R410A
3
(R410A)
Installation Manual 21
Installation
)
3

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Arnu763b8z4Arnu963b8z4