Table 1-2. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
E0000
OVRFLW CHECK LOG LCD overflow message.
E0119
TEMP AMBIENT
TEMP BMC
E0119
TEMP RISER
E0212
VOLT PG n
E0212
VOLT BATT ROMB
E0212
VOLT BATT CMOS
E0212
VOLT RISER 5V
VOLT RISER
E0412
RPM FAN n
FAN REDUNDANCY
LOST
Causes
A maximum of three error
messages can display sequentially
on the LCD. The fourth message
displays as the standard overflow
message.
Ambient system temperature is
out of acceptable range.
Riser card is out of acceptable
temperature range.
System power supply is out of
acceptable voltage range; faulty
or improperly installed power
supply.
Faulty RAID battery.
Faulty system battery.
Riser card voltage is out of
acceptable range; faulty or
improperly installed power
supply; faulty system board.
Specified cooling fan is faulty,
improperly installed, or missing.
Corrective Actions
Check the SEL for details
on the events.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide.
Replace the RAID battery.
See "Activating the Optional
Integrated RAID Controller"
in your Installation and
Troubleshooting Guide.
Replace the system battery.
See "System Battery" in your
Installation and Troubleshooting
Guide.
Reinstall the expansion-card cage.
See "Installing the Expansion-
Card Cage" in your Installation
and Troubleshooting Guide. If the
problem persists, see "Getting
Help" in your Installation and
Troubleshooting Guide.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
Information Update
7